Evaluation of ion collection area in Faraday probes.
نویسندگان
چکیده
A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.
منابع مشابه
A Comparison of Nude and Collimated Faraday Probes for Use with Hall Thrusters
* Presented as Paper IEPC-01-020 at the 27 International Electric Propulsion Conference, Pasadena, CA, 15-19 October 2001. † Copyright © 2001 by Richard Hofer. Published by the Electric Rocket Propulsion Society with permission. The effectiveness of collimated Faraday probes in obtaining the ion current density profile in Hall thrusters is investigated. A collimated probe design is attractive b...
متن کاملThe Effects of Nude Faraday Probe Design and Vacuum Facility Backpressure on the Measured Ion Current Density Profile of Hall Thruster Plumes
The effects of dissimilar probe design and facility backpressure on the measured ion current densities of Hall thrusters are investigated. JPL and GRC designed nude Faraday probes are used to simultaneously measure the ion current density of a 5 kW Hall thruster in the Large Vacuum Test Facility (LVTF) at the University of Michigan. The probes are located one meter from the exit plane of the Ha...
متن کاملEvaluation of Plume Divergence and Facility Effects on Far-Field Faraday Probe Current Density Profiles
A Faraday probe with three concentric rings was designed and fabricated to assess the effects of gap width and probe geometry in a systematic study of the Hall thruster plume. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collector. Two versions of the outer collector w...
متن کاملSingle-String Integration Test Measurements of the NEXT Ion Engine Plume
Measurements were made of a 40 cm ion-thruster plume as part of the single-string-integration-test (SSIT) activity of Phase I of the NASA’s Evolutionary Xenon Thruster (NEXT) project. The NEXT ion engine incorporates design improvements that extend NSTAR power levels and efficiencies. During SSIT, an engineering model (EM2) 40 cm engine was operated using an advanced xenon propellant system in ...
متن کاملMagnetically insulated baffled probe for real-time monitoring of equilibrium and fluctuating values of space potentials, electron and ion temperatures, and densities.
By restricting the electron-collection area of a cold Langmuir probe compared to the ion-collection area, the probe floating potential can become equal to the space potential, and thus conveniently monitored, rather than to a value shifted from the space potential by an electron-temperature-dependent offset, i.e., the case with an equal-collection-area probe. This design goal is achieved by com...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 81 6 شماره
صفحات -
تاریخ انتشار 2010