Measuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy

نویسندگان

  • Jay W. McLaren
  • Katrin Wacker
  • Katrina M. Kane
  • Sanjay V. Patel
چکیده

PURPOSE We compared corneal backscatter estimated from a Scheimpflug camera with backscatter estimated from a clinical confocal microscope across a wide range of corneal haze. METHODS A total of 59 corneas from 35 patients with a range of severity of Fuchs' endothelial corneal dystrophy and 15 corneas from 9 normal participants were examined using a Scheimpflug camera (Pentacam) and a confocal microscope (ConfoScan 4). The mean image brightness from the anterior 120 μm, midcornea, and posterior 60 μm of the cornea across the central 2 mm recorded by the Scheimpflug camera and analogous regions from the confocal microscope were measured and standardized. Differences between instruments and correlations between backscatter and disease severity were determined by using generalized estimating equation models. RESULTS Backscatter measured by the two instruments in the anterior and midcornea were correlated (r = 0.67 and 0.43, respectively, P < 0.001), although in the posterior cornea they were not correlated (r = 0.13, P = 0.66). Measured with the Scheimpflug camera, mean backscatter from the anterior and midcornea were greater, whereas backscatter from the posterior cornea was lower (P < 0.001) than that measured by the confocal microscope. Backscatter from the anterior cornea was correlated with disease severity for both instruments (Scheimpflug, r = 0.55, P < 0.001; confocal, r = 0.49, P = 0.003). CONCLUSIONS The Scheimpflug camera and confocal microscope should not be used interchangeably to measure corneal haze. The ability to detect changes in backscatter with disease severity is superior with the Scheimpflug camera. However, the confocal microscope provides higher resolution of corneal structure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Natural history of corneal haze after collagen crosslinking for keratoconus and corneal ectasia: Scheimpflug and biomicroscopic analysis.

PURPOSE To determine the natural history of collagen crosslinking (CXL)-associated corneal haze measured by Scheimpflug imagery and slitlamp biomicroscopy in patients with keratoconus or ectasia after laser in situ keratomileusis. SETTING Cornea and refractive surgery subpecialty practice, United States. DESIGN Prospective randomized controlled clinical trial. METHODS The treatment group ...

متن کامل

Standardization of corneal haze measurement in confocal microscopy.

PURPOSE Corneal stromal haze cannot be compared in longitudinal studies or across laboratories without standardization. In this study, a method was devised of standardizing image brightness in confocal microscopy of the cornea. METHODS Thirty-six normal corneas of 18 untreated volunteers and 35 corneas of 18 patients 3 years after LASIK were examined by slit scanning confocal microscopy. The ...

متن کامل

Persistent Subepithelial Haze in Thin - fl ap

PURPOSE: To report persistent subepithelial haze in two patients following femtosecond LASIK associated with creation of a thin fl ap. METHODS: Subepithelial haze was assessed by slit-lamp photography, high-resolution Scheimpfl ug imaging, and corneal confocal microscopy. RESULTS: Two patients showed distinct subepithelial haze and reduced corrected distance visual acuity at 3 months after LASI...

متن کامل

Posterior linear stromal haze formation after simultaneous photorefractive keratectomy followed by corneal collagen cross-linking.

PURPOSE To report the development of posterior linear stromal haze after simultaneous photorefractive keratectomy (PRK) followed by corneal collagen cross-linking (CXL). METHODS Combined simultaneous customized PRK followed by corneal collagen cross-linking was performed in 23 patients (28 eyes) with keratoconus. Corneas were examined biomicroscopically and by means of confocal microscopy bef...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016