Iterative reconstruction incorporating positron range correction within STIR framework
نویسندگان
چکیده
Division of Medical Physics, University of Leeds, UK Positron range is one important physical limitation to spatial resolution in PET imaging. We present a method to take account of positron range blurring in iterative reconstruction by including specific positron range kernels approximating the annihilation distribution in the forward projection operation [1]. The correction method is implemented within the OSMAPOSL iterative reconstruction algorithm of STIR 3.0 [2]. GATE [3] simulation package was used to obtain the positron annihilation distribution of a point source of 68Ga placed in the centre of spherical water and lung tissue phantoms. The simulations were performed without and with 3T static magnetic field in the axial direction. To obtain the kernels the annihilation coordinates were voxelized into a 3D matrix with element size equal to the reconstructed image’s voxel size and then normalised. The proposed method was evaluated using simulation data (generated with STIR) of a parallelepiped water phantom containing two spherical hot spots, on the HYPERImage preclinical PET/MR scanner [4]. To simulate the positron range effect the phantom was blurred by convolution with the positron kernel relative to water. The blurred images were reconstructed with and without filtering of the forward projected image. Line profiles traced through the spots of the reconstructed images show that the use of the positron range correction yields sharper boundary definition, albeit with noise enhancement. The values relative to the spots volume show that the correction results in the recovery of the activity mean value compared to the simulated phantom (e.g. 55% to 94% for the smaller spot, no magnetic field). Furthermore the tissue-dependent correction, which consists in blurring the image with the kernel correspondent to the voxel tissue (water or lung), was implemented and evaluated on a phantom with water and lung regions. The activity mean value is recovered but the method performance in correspondence to the edges needs further investigation.
منابع مشابه
PET iterative reconstruction incorporating an efficient positron range correction method.
Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image r...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملImage reconstruction of mMR PET data using the open source software STIR
Centre for Medical Image Computing, University College London, London, UK Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain op...
متن کاملMultilevel Bayesian Image Reconstruction and Better Priors for Positron Emission Tomography
The aim of this work is to support the better quantification of Positron Emission Tomography (PET) images on the basis of associated structural information. This would involve an addressal of the Partial Volume Effect (PVE) [1], which basically demands better resolution data. To this end, one approach is to apply image space correction techniques that adjust the data on the basis of compartment...
متن کامل