SU-E-T-590: Procedure for Verification and Inter-Comparison of IMRT Beam Models.

نویسندگان

  • I Veltchev
  • E Fourkal
  • R Price
  • C Ma
چکیده

PURPOSE The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quality of an IMRT beam model in comparison with other versions of the same model is central to this work. METHODS We make an important distinction between evaluation of the beam model and evaluation of the optimization routine that is a part of any IMRT planning system. The H-shaped target used in this work has several important features: it can only be covered by segments with small field size, for which all leaf design effects are important, and it has the overall dimensions of a common IMRT target. The procedure for inter-comparison of two IMRT beam models (old and new) involves the generation of two plans optimized with each beam model using identical IMRT prescriptions. Both plans are subsequently delivered on a solid water phantom with film located in two parallel planes with a small-volume ionization chamber inserted in the center. RESULTS Four dose calculations are performed, such that each plan is calculated with either of the two beam models. The four dose distributions are subsequently compared with the two film measurements using gamma analysis. In addition, the absolute dose measured in the center of the dose distribution is compared with the calculated value. A score is assigned to each beam model based on the results. CONCLUSIONS Using the procedure outlined in this presentation, different versions of an IMRT beam model can be compared and scored for quality. Adoption of a unified strategy for beam model inter-comparison can greatly facilitate the evaluation and commissioning of IMRT beam models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part19  شماره 

صفحات  -

تاریخ انتشار 2012