A high-bandwidth amplitude estimation technique for dynamic mode atomic force microscopy.
نویسندگان
چکیده
While often overlooked, one of the prerequisites for high-speed amplitude modulation atomic force microscopy is a high-bandwidth amplitude estimation technique. Conventional techniques, such as RMS to DC conversion and the lock-in amplifier, have proven useful, but offer limited measurement bandwidth and are not suitable for high-speed imaging. Several groups have developed techniques, but many of these are either difficult to implement or lack robustness. In this contribution, we briefly outline existing amplitude estimation methods and propose a new high-bandwidth estimation technique, inspired by techniques employed in microwave and RF circuit design, which utilizes phase cancellation to significantly improve the performance of the lock-in amplifier. We conclude with the design and implementation of a custom circuit to experimentally demonstrate the improvements and discuss its application in high-speed and multifrequency atomic force microscopy.
منابع مشابه
An ultra-fast scheme for sample-detection in dynamic-mode Atomic Force Microscopy
In typical dynamic mode operation of atomic force microscopes steady state signals like amplitude and phase are used for detection and imaging of material. In these methods, high quality factor of the cantilever results in high resolution, but low bandwidth and vice versa. In this paper we present a methodology that exploits the deflection signal during the transients of the cantilever motion. ...
متن کاملEffects of Fluid Environment Properties on the Nonlinear Vibrations of AFM Piezoelectric Microcantilevers
Nowadays, atomic-force microscopy plays a significant role in nanoscience and nanotechnology, and is widely used for direct measurement at atomic scale and scanning the sample surfaces. In tapping mode, the microcantilever of atomic-force microscope is excited at resonance frequency. Therefore, it is important to study its resonance. Moreover, atomic-force microscopes can be operated in fluid e...
متن کاملSensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...
متن کاملDirect tip-position control using magnetic actuation for achieving fast scanning in tapping mode atomic force microscopy
This article presents the development of a faster control loop for oscillation amplitude regulation in tapping mode operation of atomic force microscopy. Two techniques in relation to actuation and measurement are developed, that together significantly increase the bandwidth of the control loop. Firstly, magnetic actuation is employed to directly control the tip position of the cantilever to im...
متن کاملTransient-signal-based sample-detection in atomic force microscopy
In typical dynamic mode operation of atomic force microscopes, steady state signals like amplitude and phase are used for detection and imaging of material. In these methods, the resolution and bandwidth are dictated by the quality factor (Q) of the cantilever. In this letter, we present a methodology that exploits the deflection signal during the transient of the cantilever motion. The princip...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 85 2 شماره
صفحات -
تاریخ انتشار 2014