The clinical effects of low-dose splenic irradiation combined with chest three-dimensional conformal radiotherapy on patients with locally advanced non-small-cell lung cancer: a randomized clinical trial

نویسندگان

  • Hongsheng Yu
  • Yong Qu
  • Qingjun Shang
  • Chao Yan
  • Peng Jiang
  • Xiang Wang
  • Donghai Liang
  • Tao Jiang
چکیده

OBJECTIVE The objective of this study was to explore the clinical effects of low-dose splenic irradiation on locally advanced non-small-cell lung cancer (NSCLC) patients. METHODS Thirty-eight patients with stage III NSCLC were randomly divided into a control group and a combined treatment group. The control group only received chest three-dimensional conformal radiotherapy, while the combined treatment group received low-dose splenic irradiation followed by chest three-dimensional conformal radiotherapy after 6 hours. T lymphocyte subsets of the blood cells were tested before, during, and after treatment once a week. The side effects induced by radiation were observed, and a follow-up was done to observe the survival statistics. RESULTS The ratio differences in CD4(+) cells, CD8(+) cells, and CD4(+)/CD8(+) before and after treatment were not statistically significant (P>0.05) in both the groups. The immune indexes were also not statistically significant (P>0.05) before and after radiotherapy in the combined treatment group. However, the numbers of CD4(+) cells and CD4(+)/CD8(+) ratios before radiotherapy were higher than after radiotherapy in the control group. There were no differences in the incidence of radiation toxicities between the two groups; however, the incidence of grade III or IV radiation toxicities was lower, and the dose at which the radiation toxicities appeared was higher in the combined treatment group. The total response rate was 63.16% (12/19) in the combined treatment group vs 42.11% (8/19) in the control group. The median 2-year progression-free survival (15 months in the combined treatment group vs 10 months in the control group) was statistically significant (P<0.05). The median 2-year overall survival (17.1 months in the combined treatment group vs 15.8 months in the control group) was not statistically significant (P>0.05). CONCLUSION Low-dose radiation can alleviate the radiation toxicities, improve the short-term efficacy of radiotherapy, and improve the survival of locally advanced NSCLC patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Meta-analysis comparing higher and lower dose radiotherapy for palliation in locally advanced lung cancer

The purpose of this meta-analysis was to compare higher dose (≥30 Gy) and lower dose (<30 Gy) radiotherapy (RT) on palliation of symptoms and survival in patients with locally advanced lung cancer. A search of PubMed and Google Scholar was conducted on 10 June 2013 using combinations of the search terms: radiotherapy, non-small-cell lung carcinoma, palliative, supportive, symptom relief. Inclus...

متن کامل

Concurrent chemoradiotherapy in locally advanced non-small cell lung cancer: a retrospective analysis of the correlation between radiotherapy-related factors and tumor response

Background: To determine which radiotherapy parameters are associated with the tumor response of locally advanced non-small cell lung cancer (NSCLC) patients undergoing concurrent chemoradiotherapy. Materials and Methods: Thirty one patients with IIIA/IIIB NSCLC underwent chemoradiotherapy with a median dose of 63 Gy. On our actual treatments, we made radiotherapy planning to cover the planning...

متن کامل

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

Axillary irradiation in breast cancer; does meticulous contouring make a difference?

Background: Due to the current trends towards replacing axillary dissection with radiotherapy, the need for more precise definition for different nodal stations becomes a must to ensure safe and adequate dose coverage. So, our study aimed to evaluate the coverage of axillary nodal volumes based on Project on Cancer of the Breast (PROCAB) guidelines, for cases previously treated with our standar...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016