Computerized 3-dimensional localization of a video capsule in the abdominal cavity: validation by digital radiography.
نویسندگان
چکیده
BACKGROUND Wireless video capsule endoscopy allows the noninvasive visualization of the small intestine. Currently, capsules do not provide localization information while traversing the GI tract. OBJECTIVE To report on the radiological validation of 3-dimensional localization software incorporated in a newly developed capsule. By using radiofrequency transmission, the software measures the strength of the capsule's signal to locate the position of the capsule. SETTING This study was performed at the University of Massachusetts Medical Center, Worcester, Mass. PATIENTS Thirty healthy volunteers consented to the experimental procedure. DESIGN After ingestion of the capsule, subjects had 5 sets of anteroposterior and lateral radiographs taken every 30 minutes while the software calculated the position of the capsule. By using the radiographs, we calculated the location of the capsule in the abdominal cavity and compared the results with those generated by the software. RESULTS Average error (and standard deviation) among the 3-dimensional coordinates was X, 2.00 cm (1.64); Y, 2.64 cm (2.39); and Z, 2.51 cm (1.83). The average total spatial error among all measurements was 13.26 cm(3) (22.72). There was a correlation between increased subject body mass index and the 3-dimensional software measurement error. LIMITATIONS This study was performed in healthy volunteers and needs further validation in patients with small intestinal disorders. CONCLUSIONS The new 3-dimensional software provides localization of the capsule consistent with radiological observations. However, further validation of the software's clinical utility is required with a prospective clinical trial.
منابع مشابه
Comparison of computerized digital and analog radiography for detection of bronchial pattern in dogs
Background: Analog radiography has been replaced with digital radiography for canine diagnostic imaging in many veterinary clinics. There is no data comparing these modalities in a veterinary clinical setting to detect bronchial pattern signs in dogs. Objectives: In this study, computerized digital radiography (CR) and analog radiography were compared for diagnosis of bronchial pattern in dogs....
متن کاملEffective Dose Evaluation of Critical Organes in Digital Radiography Exames
Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose...
متن کاملمقایسۀ تأثیر مداخلهای بازیهای ویدیویی سه بعدی و دو بعدی بر خلاقیت و مهارتهای اجتماعی دانشجویان پسر
In recent years, there has been an increase in the playing of digital games in children, adolescents and adults worldwide. Not only has interest in digital games grown dramatically, but variations in the types of games in different fields have also occurred. An example is the emergence of three- and two-dimensional games. Based on this, the purpose of this study was to investigate the effect of...
متن کاملDose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia
Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients. Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...
متن کاملEfficacy of the Edge Enhancement Filter of Digital Radiography in the Detection of Proximal Enamel Caries in Premolars
Background and Aim: Considering the significance of the detection of proximal caries and the limited information available on the diagnostic value of digital radiography after the use of enhancement filters, this in-vitro study sought to compare the diagnostic value of digital radiography with and without the use of the edge enhancement (EE) filter in the detection of proximal enamel caries in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Gastrointestinal endoscopy
دوره 79 4 شماره
صفحات -
تاریخ انتشار 2014