Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism.
نویسندگان
چکیده
PURPOSE Description of total corneal refractive power (TCRP) astigmatism by ray tracing using a Scheimpflug tomographer. METHODS Analysis of Scheimpflug tomography measurements to determine 3-mm-zone TCRP astigmatism (CATCRP) by ray tracing calculations, astigmatism in 15°-zone from simulated keratometry (CASim-K), anterior-surface astigmatism (CAant), and posterior-surface astigmatism (CApost). An analysis of changes with age was performed. The error produced by estimating CATCRP using CASim-K was calculated through vector analyses. The percentages of steep meridian aligned vertically, obliquely, and horizontally of CAant and CApost were calculated. RESULTS A total of 3818 healthy, previously unoperated eyes were analyzed. The mean magnitude of CApost was -0.33 diopter (D). A vertically aligned steep meridian (60° to 120°) was found in 71.2% of eyes for CAant and in 88.8% for CApost. With increasing age, the occurrence of steep meridian aligned horizontally in CAant increased from 9.1% (age 20-29 years) to 31.8% (70-79 years), while vertical alignment decreased from 77.4% to 48.1%. Alignment of CApost mostly remained vertical (90.9%-80.7%). When CAant is vertical, CApost is vertical in 97% and CASim-K overestimates total corneal astigmatism (mean 0.11 ± 0.22 D). When CAant is horizontal, 18% of CApost is horizontal and CASim-K underestimates (mean 0.26 ± 0.31 D) total corneal astigmatism. The mean vector difference between CATCRP and CASim-K was 0.18 at 178° and exceeded 0.50 D in 9% of eyes. CONCLUSIONS Total corneal astigmatism is overestimated by CASim-K in eyes with with-the-rule astigmatism and cannot be predicted safely in eyes that do not have with-the-rule astigmatism by anterior measurements only.
منابع مشابه
Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik
Swept-source optical coherence tomography (OCT) is the latest advancement in anterior segment imaging. There are limited data regarding its performance after laser in situ keratomileusis (LASIK). We compared the reliability of swept-source OCT and Scheimpflug imaging for evaluation of corneal parameters in refractive surgery candidates with myopia or myopic astigmatism. Three consecutive measur...
متن کاملContribution of posterior corneal astigmatism to total corneal astigmatism.
PURPOSE To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer. SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Case series. METHODS Total corneal astigmatism was calculated using ray trac...
متن کاملPosterior corneal astigmatism.
In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...
متن کاملTomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus.
PURPOSE To analyze and compare changes to the anterior and posterior corneal surfaces after Ferrara intracorneal ring segment (ICRS) (AJL, Boecillo, Spain) implantation and to correlate those changes with visual outcomes. METHODS This retrospective case series study comprised consecutive patients with keratoconus implanted with the Ferrara ICRS. Computed tomography scans of the two corneal su...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2014