Tracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: comparison with quantitative single-photon emission CT.

نویسندگان

  • M Sasaki
  • K Kudo
  • K Ogasawara
  • S Fujiwara
چکیده

BACKGROUND AND PURPOSE Reliability of CT perfusion (CTP) algorithms has not been fully validated. We investigated whether the cerebral blood flow (CBF) values obtained by using a dynamic CTP technique with a tracer delay-insensitive deconvolution algorithm are more accurate than those obtained by using CTP with delay-sensitive algorithms in unilateral cerebrovascular steno-occlusive disease, when compared with those generated by quantitative single-photon emission CT (SPECT). MATERIALS AND METHODS Using CTP and iodine-123-N-isopropyl-p-iodoamphetamine SPECT with an autoradiographic quantification technique, we examined 20 patients with suggested hemodynamic ischemia due to stenosis or occlusion of the unilateral internal carotid or middle cerebral artery. The algorithms used for CTP included delay-insensitive block-circulant singular value decomposition (SVD) (bSVD) and delay-sensitive standard SVD (sSVD) and box-modulation transfer function (bMTF). RESULTS Absolute CBF values obtained by using CTP with bSVD were significantly lower than those obtained with SPECT, but the ratios to the nonaffected side were significantly correlated to the quantitative SPECT values with significant agreements, particularly when the arterial input function was obtained from the unaffected side. Contrastingly, CBF ratios with sSVD and bMTF were significantly underestimated, and no significant agreement was determined between CTP with sSVD or bMTF and SPECT, though there were substantial correlations between them in some parameters. CONCLUSIONS With the CTP technique, the insensitivity of the deconvolution algorithm to the tracer-delay effect appears to be essential for estimating semiquantitative CBF values in patients with unilateral steno-occlusive lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of superficial temporal artery-middle cerebral artery bypass in cerebrovascular steno-occlusive diseases: Hemodynamics assessed by perfusion computed tomography

OBJECTIVES Our purpose of this study was to assess the cerebral hemodynamic improvement with perfusion computed tomography (CT), before and after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in patients with cerebrovascular steno-occlusive diseases including both moyamoya disease and nonmoyamoya steno-occlusions. MATERIALS AND METHODS Twenty-four STA-MCA by...

متن کامل

Dynamic CT perfusion imaging with acetazolamide challenge for evaluation of patients with unilateral cerebrovascular steno-occlusive disease.

BACKGROUND AND PURPOSE Perfusion CT (PCT) has the ability to measure quantitative values and produce maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). We assessed cerebral hemodynamics by using these parameters and acetazolamide challenge in patients with cerebrovascular steno-occlusive disease. METHODS Fifteen patients underwent PCT with acetazolami...

متن کامل

Simple assessment of cerebral hemodynamics using single-slab 3D time-of-flight MR angiography in patients with cervical internal carotid artery steno-occlusive diseases: comparison with quantitative perfusion single-photon emission CT.

BACKGROUND AND PURPOSE Visualization of the peripheral arteries on single-slab 3D time-of-flight (TOF) MR angiography (MRA) can reflect blood flow velocity. The velocity in the middle cerebral artery (MCA) may correlate with cerebrovascular reactivity (CVR) to acetazolamide, which can be used to assess hemodynamic impairment. The goal of this study was to compare the signal intensity of the MCA...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2009