Noise-equivalent sensitivity of photoacoustics.
نویسندگان
چکیده
The fundamental limitations of photoacoustic microscopy for detecting optically absorbing molecules are investigated both theoretically and experimentally. We experimentally demonstrate noise-equivalent detection sensitivities of 160,000 methylene blue molecules (270 zeptomol or 2.7×10-19 mol) and 86,000 oxygenated hemoglobin molecules (140 zeptomol) using narrowband continuous-wave photoacoustics. The ultimate sensitivity of photoacoustics is fundamentally limited by thermal noise, which can present in the acoustic detection system as well as in the medium itself. Under the optimized conditions described herein and using commercially available detectors, photoacoustic microscopy can detect as few as 100s of oxygenated hemoglobin molecules. Realizable improvements to the detector may enable single molecule detection of select molecules.
منابع مشابه
ارتباط بین حساسیت و آزاردهندگی با شاخصهای صوتی (PNC,SIL) در بیمارستانهای شهر بهبهان
Introduction: A hospital as a health care institution providing treatment services can be heavily influenced by sources of noise. Noise pollution has negative impacts on patient comfort and staff welfare. This study aimed to evaluate the relationship between noise annoyance and sensitivity with noise parameters (PNC, SIL) in the hospitals of Behbahan. Methods: This study...
متن کاملInvestigating the effect of noise exposure on mental workload, noise sensitivity and general and mental health of overhead crane operators in one of the Steel Industries in south of Iran
Introduction: Overhead cranes play a vital role in guiding steel industries and maintaining their normal condition. These machines are operated by humans and pose a great risk of accidents that may occur due to mistakes made by operators. According to the mentioned contents, the non-negligible effects of noise on the physical and mental health of people in the work environment, the complexity a...
متن کاملA survey of the effect of toluene on the impact of noise on hearing loss in workers
Background: Ototoxic chemicals can impair the sense of hearing and balance. In the past decades, the ototoxicity of solvents and their interaction with noise have become evident. This study has been carried out in the shoe manufacturing factory in Tehran (Iran) with the aim of evaluating the combined effects of noise and toluene on the workers' hearing. Materials and Methods: This cross-sect...
متن کاملبررسی آلودگی صوتی در کارگاههای تراشکاری و صافکاری شهر قم و مقایسه آن با استاندارد صدای کشوری
Introduction and purpose: Noise pollution is an important health problem in most industries, especially in the small inland industries. The purpose of this study was to evaluate the noise pollution in turning and polishing shops in Qom, Iran, and compare it with the sound standards in the country. Methods: In the present descriptive cross-sectional study, noise assessment was performed using th...
متن کاملSensitivity of photoacoustic microscopy
Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2013