Catheter Ablation of the Atrial Myocardium in Human Type I Atrial
نویسنده
چکیده
was attempted in eight patients with drug refractory type I atrial flutter. In seven of eight patients, a zone of prolongation and fragmentation of the endocardial electrogram was found in the low posterior part of the right atrium. Entrainment of the atrial flutter by high right atrial pacing was accompanied by local recording of second-degree regional block in several atrial sectors but never in the low septal area. We, therefore, hypothesized that the latter represented the critical slow conduction zone of the reentrant flutter circuit. One or two cathodal DC shocks were locally delivered without immediate or late complications. One single ablation attempt was performed in five patients, whereas three patients underwent a second attempt because of early flutter recurrence. Patients were initially discharged without (and after a second session with) antiarrhythmic drugs. After a mean follow-up of 15.5 months (range, 10-23 months), five patients are free of arrhythmias without antiarrhythmic drug therapy. Two patients did not experience atrial arrhythmias while on a drug regimen that was previously found to be ineffective, and a third patient had flutter recurrences. This study suggests that patients with type I atrial flutter referred for atrioventricular node-His bundle ablation may be successfully managed by delivering the ablative shock directly on the atrial arrhythmia substrate. (Circulation 1990;81:762-771)
منابع مشابه
Catheter ablation of the atrial myocardium in human type I atrial flutter.
To avoid atrioventricular node-His bundle ablation, catheter ablation of the atrial myocardium was attempted in eight patients with drug refractory type I atrial flutter. In seven of eight patients, a zone of prolongation and fragmentation of the endocardial electrogram was found in the low posterior part of the right atrium. Entrainment of the atrial flutter by high right atrial pacing was acc...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملRadiofrequency ablation in treatment of atrial fibrillation.
Beside heart failure and metabolic syndrome, atrial fibrillation is termed the cardiovascular epidemic of the twenty-first century. Its increased morbidity and mortality is alarming. The present, most effective therapy of atrial fibrillation is catheter ablation. Successful ablation of atrial fibrillation prevents the occurrence and progression of electrical, structural and mechanic myocardium ...
متن کاملContact force technology in catheter ablation of atrial fibrillation
Catheter ablation of atrial fibrillation (AF) has an indisputable value in the treatment of patients with symptomatic drug refractory AF. Nowadays, special interest is paid to improve the efficacy and the safety of the procedure and new approaches allowing better understanding of the lesions creation and its control have been developed. A lot of factors including power and duration of energy de...
متن کامل