Resolution in electron microscope autoradiography. III. Iodine-125, the effect of heavy metal staining, and a reassessment of critical parameters

نویسندگان

  • M M Salpeter
  • H C Fertuck
  • E E Salpeter
چکیده

Resolution for 125I-labeled specimens under electron microscope (EM) autoradiographic conditions was assessed experimentally. With this isotope the size of the silver halide crystal was the most important resolution-limiting factor. Heavy metal staining such as is routinely used in preparing animal tissues for EM autoradiography produced an improvement in resolution of approximately 15-20%. For a 500-1,000-A biological tissue section fixed with OsO4 and stained with uranyl acetate, we obtained resolution (half distance, HD) values of approximately 800 +/- 120 A using Ilford L4 emulsion and 500 +/- 70 A using a Kodak NTE-type emulsion. General aspects of resolution-limiting factors and comparison with 3H and 14C values are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional microstructure characterisation of thermoplastic polyolefin blends.

The size, shape and distribution of different phases in thermoplastic polyolefin (TPO) blends and composites are critical to the properties of the materials, but can be difficult to characterise. Here we report the combination of heavy metal staining and focused ion beam - scanning electron microscopy (FIB-SEM) to reveal the three-dimensional (3D) structure of an elastomer-modified poly(propyle...

متن کامل

THE USE OF SPECIFIC ANTIBODY IN ELECTRON MICROSCOPY III. Localization of Antigens by the Use of Unmodified Antibody

Antibody staining was observcd in the clcctron microscope by means of untagged antibody and osmium fixation. The antibody was visualized as a change in morphology due to its deposition on the antigcnic structures. Glyccrinatcd chicken breast musclc was stained with antimyosin, anti-H-meromyosin, and antiactin. The staining pattcrns obtained by electron microscopy werc consistcnt with those prev...

متن کامل

Effective Removal of Heavy Metal Ions Zn2+, Ni2+, Cu2+, Cr3+ from Aqueous Solution by Synthetic Superabsorbent Polymer

Heavy  metal  pollution  is  propagating  throughout  the  world  with  the  enlargement  of  industrial activities.  The  elimination  of  heavy  metal  ions  from  industrial  wastewaters  has  drawn  much attention  because  of  the  hazardous  effects  of  the  heavy  metal  ions  on  different  organisms. According to these facts, poly (2, 2, 3, 3- tetracyanocyclopropyl) phenyl acryl...

متن کامل

The Kinetics and Mechanism of Oxidation of the N-Substituted Urea-Titanium (III) Complexes by Iodine (AS I-3) in Ethanol and Acetonitrile

The oxidation of complexes of Ti(III), (TiL6)3+ (L=ur, Meur, DMeur, DEture, N-Bu-ur, and Phur), by iodine as I3- in ethanol and acetonitrile solutions, appears to proceed as a second order reaction and is much faster in ethanol solution (where solvolysis occurs) than in acetonitrile. The enthalpy of activation appears to decrease as ligand's size ...

متن کامل

THE USE OF SPECIFIC ANTIBODY IN ELECTRON MICROSCOPY III. Localization of Antigens by the Use of Unmodified Antibody

Antibody staining was observcd in the clcctron microscope by means of untagged antibody and osmium fixation. The antibody was visualized as a change in morphology due to its deposition on the antigcnic structures. Glyccrinatcd chicken breast musclc was stained with antimyosin, anti-H-meromyosin, and antiactin. The staining pattcrns obtained by electron microscopy werc consistcnt with those prev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Cell Biology

دوره 72  شماره 

صفحات  -

تاریخ انتشار 1977