Artifact-free matrix-assisted laser desorption ionization time-of-flight mass spectra of tert.-butyldimethylsilyl ether derivatives of cyclodextrins used for the synthesis of single-isomer, chiral resolving agents for capillary electrophoresis.

نویسندگان

  • W K Russell
  • D H Russell
  • M B Busby
  • A Kolberg
  • S Li
  • D K Maynard
  • S Sanchez-Vindas
  • W Zhu
  • G Vigh
چکیده

Artifact-free, high-resolution matrix-assisted laser desorption ionization (MALDI) time-of-flight mass spectra have been obtained for the labile, single-isomer, tert.-butyldimethylsilyl ether derivatives of alpha-, beta- and gamma-cyclodextrins by optimizing the MALDI sample preparation method. 2,5-Dihydroxybenzoic acid, a 3:1 mixture of 2,5-dihydroxybenzoic acid and 1-hydroxyisoquinoline, and 2,4,6-trihydroxyacetophenone were investigated as MALDI matrices with methanol and acetonitrile as matrix solvents. Partial-to-complete loss of the tert.-butyldimethylsilyl groups was observed when the commonly used 2,5-dihydroxybenzoic acid was the MALDI matrix and/or methanol was the solvent, both with and without trifluoroacetic acid as additive. Loss of the labile tert.-butyldimethylsilyl groups was avoided with 2,4,6-trihydroxyacetophenone as MALDI matrix and acetonitrile as matrix solvent. Good ion intensities were achieved for the (M+Na)+ and (M+K)+ quasimolecular ions in the positive-ion mode. Minor byproducts were observed in some of the samples and the information was used to aid the optimization of the synthetic work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Immobilized metal-ion chelating capillary microreactor for peptide mapping analysis of proteins by matrix assisted laser desorption/ ionization-time of flight-mass spectrometry.

Peptide mass mapping analysis, utilizing a regenerable enzyme microreactor with metal-ion chelated adsorption of enzyme, combined with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) was developed. Different procedures from the conventional approaches were adopted to immobilize the chelator onto the silica supports, that is, the metal chelating agent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 914 1-2  شماره 

صفحات  -

تاریخ انتشار 2001