Characterization of a miniature, ultra-high-field, ion mobility spectrometer

نویسندگان

  • Ashley Wilks
  • Matthew Hart
  • Andrew Koehl
  • John Somerville
  • Billy Boyle
  • David Ruiz-Alonso
چکیده

By combining a multiple micron-gap ion separator with a novel high-frequency separation waveform drive topology, it has been possible to considerably extend the separation field limits employed in Field Asymmetric Ion Mobility Spectrometry (FAIMS)/Differential Mobility Spectrometry (DMS); giving rise to an Ultra-High-Field operational domain. A miniature spectrometer, based around the multi-micron-gap ion separator and ultra-high-field drivers, has been developed to meet the continuing industrial need for sensitive (sub-ppm), broadband and fast (second timescale) response volatile chemical detection. The packaged miniature spectrometer measures 12×12×15 cm, weighs 1.2 kg and is fully standalone; consisting of the core multi-micron gap ion separator assembly and RF/DC electronic drivers integrated with pneumatic handling/sample conditioning elements, together with ancillary temperature, flow and humidity sensing for stable closed loop operation (under local microprocessor control). The combination of multiple micron-gap ion separators with the novel highfrequency separation waveform drive topology enables ion separations to be performed over scanning electric field ranges of 0 to >75 kV·cm (0 to >∼320 Td at 101 kPa), offering a potential solution to trace and ultra-trace chemical detection/monitoring problems, that conventional IMS and DMS/FAIMS may otherwise find challenging. In this ultrahigh field operational regime effective ion temperatures may be “swept” from ambient to >1000 K because critically, the effective ion temperature scales to at least the square of the applied field. With this field induced ion heating a controlled manipulation (or switching) of the ion chemistry within the separation channel (the ion drift region) may be invoked. For example, ion fragmentation via thermal dissociation can be induced. Chemical separation and identification is thus derived from the unique kinetic and thermodynamic behavior of ions assessed over a very broad effective temperature range. In addition to describing the novel miniature spectrometer, this paper addresses key aspects of ultra-high-field operation, which render it distinct from traditional ion mobility technologies and principles. In particular, this paper essays a model of ultra-high-field operation and highlights model deviations, whilst providing clear theoretical explanation backed up with experimental evidence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field-programmable Gate Array in Miniature Ion Mobility Spectrometer Sensor System

This paper presents the use of field-programmable gate array (FPGA) in a miniature Ion Mobility Spectrometer (IMS) sensor system. This IMS sensor is for detection of subsurface gaseous volatile organic compounds (VOCs). This paper describes how an FPGA is used to process the data collected from the sensor and control its overall operation. A Xilinx Microblaze soft-core processor is used to ease...

متن کامل

Conformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross Sections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass Spectrometer

Ion mobility-mass spectrometry measurements which describe the gas-phase scaling of molecular size and mass are of both fundamental and pragmatic utility. Fundamentally, such measurements expand our understanding of intrinsic intramolecular folding forces in the absence of solvent. Practically, reproducible transport properties, such as gas-phase collision cross-section (CCS), are analytically ...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Miniaturized ultra high field asymmetric waveform ion mobility spectrometry combined with mass spectrometry for peptide analysis.

Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (ultra-FAIMS) combined with mass spectrometry (MS) has been applied to the analysis of standard and tryptic peptides, derived from α-1-acid glycoprotein, using electrospray and nanoelectrospray ion sources. Singly and multiply charged peptide ions were separated in the gas phase using ultra-FAIMS and detected by ion tra...

متن کامل

Ion mobility spectrometer with radial collisional focusing.

An ion mobility spectrometer that has its mobility cell as a 20-segment quadrupole and functionally the q2 of a triple-quadrupole mass spectrometer has been assembled and tested. The combination of high cell pressure (maximum of 4 Torr of helium) and low axial field (20-160 V per 20.2 cm) results in negligible internal excitation of the ions despite applications of rf and axial fields. The pres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012