Imaging acute thermal burns by photoacoustic microscopy.
نویسندگان
چکیده
The clinical significance of a burn depends on the percentage of total body involved and the depth of the burn. Hence a noninvasive method that is able to evaluate burn depth would be of great help in clinical evaluation. To this end, photoacoustic microscopy is used to determine the depth of acute thermal burns by imaging the total hemoglobin concentration in the blood that accumulates along the boundaries of injuries as a result of thermal damage to the vasculature. We induce acute thermal burns in vivo on pig skin with cautery. Photoacoustic images of the burns are acquired after skin excision. In a burn treated at 175 degrees C for 20 s, the maximum imaged burn depth is 1.73+/-0.07 mm. In burns treated at 150 degrees C for 5, 10, 20, and 30 s, respectively, the trend of increasing maximum burn depth with longer thermal exposure is demonstrated.
منابع مشابه
Enhanced thermal stability of silica-coated gold nanorods for photoacoustic imaging and image-guided therapy
Photothermal stability and, therefore, consistency of both optical absorption and photoacoustic response of the plasmonic nanoabsorbers is critical for successful photoacoustic image-guided photothermal therapy. In this study, silica-coated gold nanorods were developed as a multifunctional molecular imaging and therapeutic agent suitable for image-guided photothermal therapy. The optical proper...
متن کاملDevelopment of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy
Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The la...
متن کاملGrueneisen relaxation photoacoustic microscopy.
The temperature-dependent property of the Grueneisen parameter has been employed in photoacoustic imaging mainly to measure tissue temperature. Here we explore this property using a different approach and develop Grueneisen relaxation photoacoustic microscopy (GR-PAM), a technique that images nonradiative absorption with confocal optical resolution. GR-PAM sequentially delivers two identical la...
متن کاملSensitivity of photoacoustic microscopy
Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given p...
متن کاملNoninvasive assessment of burn wound severity using optical technology: a review of current and future modalities.
Clinical examination alone is not always sufficient to determine which burn wounds will heal spontaneously and which will require surgical intervention for optimal outcome. We present a review of optical modalities currently in clinical use and under development to assist burn surgeons in assessing burn wound severity, including conventional histology/light microscopy, laser Doppler imaging, in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 11 5 شماره
صفحات -
تاریخ انتشار 2006