Pulse wave velocity assessment by external noninvasive devices and phase-contrast magnetic resonance imaging in the obese.

نویسندگان

  • Laure Joly
  • Christine Perret-Guillaume
  • Anna Kearney-Schwartz
  • Paolo Salvi
  • Damien Mandry
  • Pierre-Yves Marie
  • Gilles Karcher
  • Patrick Rossignol
  • Faiez Zannad
  • Athanase Benetos
چکیده

Carotid-femoral pulse wave velocity (PWV) is considered the gold-standard measurement of arterial stiffness. Obesity, however, can render inaccurate the measurement of PWV by external noninvasive devices. Phase-contrast MRI allows the determination of aortic PWV in multiple aortic locations with intra-arterial distance measurements, as well as the assessment of aortic mechanical properties. The purpose of this study was to assess the reliability of external carotid-femoral PWV values measured by well-validated external devices in comparison with MRI acquisitions of PWV and aortic mechanical properties in a population of obese subjects. PWV was measured with PulsePen and Complior II devices in 32 volunteers (18 men and 14 women), aged 46 to 65 years (mean: 55.7+/-5.1 years), presenting with isolated abdominal obesity, with a waist circumference >102 cm for men and >88 cm for women, and a body mass index between 27 and 35. These results were then compared with MRI PWV values and cross-sectional MRI thoracic aorta distensibility values. MRI PWV values were positively correlated with PWV measured by both PulsePen (r=0.47; P=0.005) and Complior (r=0.43; P=0.01). Aortic cross-sectional stiffness was positively correlated with PulsePen PWV (r=0.42; P=0.02). The same trend was also observed with Complior PWV (r=0.33; P=0.06). This is the first study comparing transcutaneous PWV measurements with MRI aortic elastic properties in obese subjects. Our results indicate that, for body mass index values < or =35 kg m(-2), PWV measured externally with Complior or PulsePen validly reflect values obtained directly in the thoracic aorta through MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Measurement of pulse wave velocity in normal ageing: comparison of Vicorder and magnetic resonance phase contrast imaging

BACKGROUND Pulse wave velocity is an important measure of cardiovascular risk, and can be measured by several different techniques. We compared age-related changes in pulse wave velocity derived from carotid and femoral artery waveforms using the Vicorder device and descending thoracic aorta time velocity curves using phase contrast magnetic resonance imaging (MRI) in a group of normal healthy ...

متن کامل

The clinical significance of aortic compliance and its assessment with magnetic resonance imaging.

The biophysical properties of the aortic wall seems to play a significant role in the pathogenesis of cardiovascular disease such as atherosclerosis, hypertension, aneurysm formation, Marfan's syndrome, and in normal aging. The presence and the proportion of smooth muscle, collagen, and elastin proteins contribute to the compliance of the vessel wall with the latter being the most extensible co...

متن کامل

The Assessment of Toxicity Characteristics of Cellular Uptake of Paramagnetic Nanoparticles as a New Magnetic Resonance Imaging Contrast Agent

Nanoparticles are unique that enable many promising medical and technological applications intheir physical, and chemical properties. It is widely accepted that nanoparticles should bethoroughly tested for health nanotoxicity, but a moderate risk analysis is currently prevented by arevealing absence of mechanistic knowledge of nanoparticle toxicity. The purpose of this study<b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hypertension

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2009