Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.
نویسندگان
چکیده
A novel fat saturation scheme is proposed which combines spectral fat saturation with a steady-state 3D true Fast Imaging with Steady Precesson (TrueFISP) sequence. Fat saturation consisted of a conventional frequency-selective excitation pulse surrounded by spoiler gradients. This saturation block was periodically repeated within a continuously running TrueFISP sequence. Except for the fat signals, the steady-state signal formation and the resulting image contrast of TrueFISP was not modified by the periodically inserted fat saturation block. This was achieved by a alpha/2 flip-back pulse before the fat saturation block, which stores the established steady-state transverse magnetization as pure longitudinal magnetization. After fat saturation this longitudinal magnetization was excited by a alpha/2 preparation pulse to continue the TrueFISP acquisition. The resulting images show contrast identical to conventional TrueFISP images, but without the usually very bright fat signals. The short repetition time allows acquisition of a 3D data set of the abdomen within a single breath-hold.
منابع مشابه
Navigator-Gated Whole Heart Coronary MRI with 3D isotropic Double Echo TrueFISP UTE
Introduction Coronary MRA provides a non-invasive approach for the detection of coronary artery disease. Previous works have shown that whole heart 3D radial techniques simplify the scanning procedure with no compromise in image quality [1-4]. Ultra-short Echo Time (UTE) MRI allows for the detection of short T2 components (T2 of the order of 100 μs) in tissue before they have decayed [5, 6]. Th...
متن کاملRapid 3D Relaxation Time and Proton Density Quantification Using a Modified Radial IR TrueFisp Sequence
Introduction: A promising approach for the simultaneous quantification of proton density, T1 and T2 is the IR TrueFISP sequence proposed by Schmitt et al. [1]. This sequence consists of an inversion pulse followed by a series of TrueFISP acquisitions, observing a quasirelaxation towards the steady-state. However, this sequence requires a delay between individual segments in order to allow the m...
متن کاملCAIPIRINHA accelerated simultaneous multi-slice TrueFISP real-time imaging
Introduction: CAIPIRINHA multi-slice imaging offers the possibility to acquire several imaging slices simultaneously while maintaining the image quality (1), allowing a high acceleration of the imaging procedure. By providing the individual slices with different RF-phase cycles, the simultaneously excited slices are shifted with respect to each other in the FOV, facilitating the separation of t...
متن کاملMR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.
MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal ...
متن کاملIntegration of magnetization preparation sequences into SSFP sequences: A fat saturation example
Introduction: Steady state MRI-sequences are widely used for clinical applications. In particular, balanced steady-state free precession (b-SSFP) has become increasingly important for diagnostic and interventional imaging [1]. However, contrast modification by using magnetization preparation sequences, (like fat suppression or regional signal suppression), requires the use of transient steady s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 45 6 شماره
صفحات -
تاریخ انتشار 2001