Analysis of changes in corneal shape and refraction following scleral buckling surgery.

نویسندگان

  • Y Okada
  • S Nakamura
  • E Kubo
  • N Oishi
  • Y Takahashi
  • Y Akagi
چکیده

PURPOSE A prospective study was performed to investigate changes in corneal shape and axial length following scleral buckling surgery. METHODS We investigated the changes in corneal shape, refraction, and axial length following scleral buckling surgery in 24 patients who underwent local buckling and 14 patients who underwent encircling with additional segmental buckling. The corneal shape was determined by corneal topography and autokeratometry, refraction was measured by autorefractometry, and axial length was measured by A-mode ultrasonography before surgery, and 1, 2, and 7 days, and 1, 3, and 6 months after surgery. RESULTS After local buckling, the axial length shortened and a hyperopic change was observed. After encircling with additional segmental buckling, the axial length elongated and a myopic shift was detected. The direction of the surgically induced corneal astigmatic vectors was almost identical to the direction of the buckle. There was a tendency for shorter distances between the limbus and the buckle to be associated with greater absolute values. Astigmatism gradually decreased following surgery and stabilized in about 3 months. CONCLUSIONS Surgeons should select a surgical procedure to ensure favorable postoperative visual acuity while minimizing changes in the shape of the cornea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تغییرات توپوگرافیک قرنیه بعد از اعمال جراحی اسکرال با کلینگ و ویترکتومی

To investigale the topographic changes in the cornea after scleral buckling and vitrectommy. A prospective study was conducted. Thses changes were analyzed based on the type of surgical procedures performed. Design of this study was observational prospective case series. 49 eyes from 48 patients were stratified into four groups based on the type of surgical procedures performed. 10 un...

متن کامل

Circumferential silicone sponge scleral buckling induced axial length changes: case series and comparison to literature

BACKGROUND This study compared axial length changes induced by circumferential scleral buckling using a silicone sponge with literature reports for solid silicone rubber. METHODS Records of patients treated with scleral buckling in 2009-2013 using a silicone sponge, with preoperative axial length biometry measurements were reviewed. Additional information included age, type of surgery, additi...

متن کامل

Corneal topographic changes following retinal surgery

BACKGROUND To study the effect of retinal/ vitreoretinal surgeries on corneal elevations. METHODS Patients who underwent retinal/ vitreoretinal surgeries were divided into 3 groups. Scleral buckling was performed in 11 eyes (Group 1). In 8 (25%) eyes, vitreoretinal surgery was performed along with scleral buckling (Group 2). In 12 eyes, pars plana vitrectomy was performed for vitreous hemorrh...

متن کامل

Evaluation of Corneal Biomechanical Properties following Scleral Buckling Using the Ocular Response Analyzer

Purpose: To evaluate corneal visco-elasticity and intraocular pressure (IOP) changes measured by an Ocular Response Analyzer (ORA) after scleral buckling Methods: Fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated IOP (IOPcc) and Goldmann-correlated IOP (IOPg) were mea...

متن کامل

Corneal topographic changes following trans-conjunctival 20 gauge sutureless vitrectomy (TC20V)

PURPOSE To assess the occurrence and magnitude of corneal topographic changes in phakic eyes undergoing Transconjuctival Cannulated 20 gauge Vitrectomy (TC20V) without scleral buckling or silicone oil tamponade. SETTING Prospective randomized controlled study done at Egyptian Eye Academy. METHODS Forty eyes of 40 patients underwent TC20V for a variety of vitreo-retinal conditions over a 1 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of ophthalmology

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2000