Towards a benchmark simulation model for plant-wide control strategy performance evaluation of WWTPs.

نویسندگان

  • U Jeppsson
  • C Rosen
  • J Alex
  • J Copp
  • K V Gernaey
  • M N Pons
  • P A Vanrolleghem
چکیده

The COST/IWA benchmark simulation model has been available for seven years. Its primary purpose has been to create a platform for control strategy benchmarking of activated sludge processes. The fact that the benchmark has resulted in more than 100 publications, not only in Europe but also worldwide, demonstrates the interest in such a tool within the research community In this paper, an extension of the benchmark simulation model no 1 (BSM1) is proposed. This extension aims at facilitating control strategy development and performance evaluation at a plant-wide level and, consequently, includes both pre-treatment of wastewater as well as the processes describing sludge treatment. The motivation for the extension is the increasing interest and need to operate and control wastewater treatment systems not only at an individual process level but also on a plant-wide basis. To facilitate the changes, the evaluation period has been extended to one year. A prolonged evaluation period allows for long-term control strategies to be assessed and enables the use of control handles that cannot be evaluated in a realistic fashion in the one-week BSM1 evaluation period. In the paper, the extended plant layout is proposed and the new suggested process models are described briefly. Models for influent file design, the benchmarking procedure and the evaluation criteria are also discussed. And finally, some important remaining topics, for which consensus is required, are identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benchmark simulation Model no 2 in Matlab-simulink: towards plant-wide WWTP control strategy evaluation.

In this paper, implementation of the Benchmark Simulation Model No 2 (BSM2) within Matlab-Simulink is presented. The BSM2 is developed for plant-wide WWTP control strategy evaluation on a long-term basis. It consists of a pre-treatment process, an activated sludge process and sludge treatment processes. Extended evaluation criteria are proposed for plant-wide control strategy assessment. Defaul...

متن کامل

Energy and Environmental Efficiency for the N-Ammonia Removal Process in Wastewater [1.0]Treatment Plants by Means of Reinforcement Learning

Currently, energy and environmental efficiency are critical aspects in wastewater treatment plants (WWTPs). In fact, WWTPs are significant energy consumers, especially in the active sludge process (ASP) for the N-ammonia removal. In this paper, we face the challenge of simultaneously improving the economic and environmental performance by using a reinforcement learning approach. This approach i...

متن کامل

Predictive Control of Nitrogen Removal in Wwtps Using Parsimonious Models

In the paper, control possibilities for the nitrogen removal process within activated sludge wastewater treatment plants are discussed. A predictive controller is introduced which aims to reduce the peaks in effluent concentration for ammonia nitrogen. Additionally, the controller improves the overall nitrogen removal using less aeration energy. A parsimonious deterministic model is used for th...

متن کامل

Development of simulation model for performance evaluation of feed water system in a typical thermal power plant

The present paper deals with development of a simulation model for the performance evaluation of feed water system of a thermal power plant using Markov Birth-Death process and probabilistic approach. In present paper, the feed water system consists of four subsystems. After drawing transition diagram for feed water system, differential equations are developed and then solved recursively using ...

متن کامل

Plant-wide (BSM2) evaluation of reject water treatment with a SHARON-Anammox process.

In wastewater treatment plants (WWTPs) equipped with sludge digestion and dewatering systems, the reject water originating from these facilities contributes significantly to the nitrogen load of the activated sludge tanks, to which it is typically recycled. In this paper, the impact of reject water streams on the performance of a WWTP is assessed in a simulation study, using the Benchmark Simul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water science and technology : a journal of the International Association on Water Pollution Research

دوره 53 1  شماره 

صفحات  -