Improved hepatic arterial fraction estimation using cardiac output correction of arterial input functions for liver DCE MRI.

نویسندگان

  • Manil D Chouhan
  • Alan Bainbridge
  • David Atkinson
  • Shonit Punwani
  • Rajeshwar P Mookerjee
  • Mark F Lythgoe
  • Stuart A Taylor
چکیده

Liver dynamic contrast enhanced (DCE) MRI pharmacokinetic modelling could be useful in the assessment of diffuse liver disease and focal liver lesions, but is compromised by errors in arterial input function (AIF) sampling. In this study, we apply cardiac output correction to arterial input functions (AIFs) for liver DCE MRI and investigate the effect on dual-input single compartment hepatic perfusion parameter estimation and reproducibility. Thirteen healthy volunteers (28.7  ±  1.94 years, seven males) underwent liver DCE MRI and cardiac output measurement using aortic root phase contrast MRI (PCMRI), with reproducibility (n  =  9) measured at 7 d. Cardiac output AIF correction was undertaken by constraining the first pass AIF enhancement curve using the indicator-dilution principle. Hepatic perfusion parameters with and without cardiac output AIF correction were compared and 7 d reproducibility assessed. Differences between cardiac output corrected and uncorrected liver DCE MRI portal venous (PV) perfusion (p  =  0.066), total liver blood flow (TLBF) (p  =  0.101), hepatic arterial (HA) fraction (p  =  0.895), mean transit time (MTT) (p  =  0.646), distribution volume (DV) (p  =  0.890) were not significantly different. Seven day corrected HA fraction reproducibility was improved (mean difference 0.3%, Bland-Altman 95% limits-of-agreement (BA95%LoA)  ±27.9%, coefficient of variation (CoV) 61.4% versus 9.3%, ±35.5%, 81.7% respectively without correction). Seven day uncorrected PV perfusion was also improved (mean difference 9.3 ml min-1/100 g, BA95%LoA  ±506.1 ml min-1/100 g, CoV 64.1% versus 0.9 ml min-1/100 g, ±562.8 ml min-1/100 g, 65.1% respectively with correction) as was uncorrected TLBF (mean difference 43.8 ml min-1/100 g, BA95%LoA  ±586.7 ml min-1/ 100 g, CoV 58.3% versus 13.3 ml min-1/100 g, ±661.5 ml min-1/100 g, 60.9% respectively with correction). Reproducibility of uncorrected MTT was similar (uncorrected mean difference 2.4 s, BA95%LoA  ±26.7 s, CoV 60.8% uncorrected versus 3.7 s, ±27.8 s, 62.0% respectively with correction), as was and DV (uncorrected mean difference 14.1%, BA95%LoA  ±48.2%, CoV 24.7% versus 10.3%, ±46.0%, 23.9% respectively with correction). Cardiac output AIF correction does not significantly affect the estimation of hepatic perfusion parameters but demonstrates improvements in normal volunteer 7 d HA fraction reproducibility, but deterioration in PV perfusion and TLBF reproducibility. Improved HA fraction reproducibility maybe important as arterialisation of liver perfusion is increased in chronic liver disease and within malignant liver lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of contrast agent bolus arrival delays for improved reproducibility of liver DCE MRI

Delays between contrast agent (CA) arrival at the site of vascular input function (VIF) sampling and the tissue of interest affect dynamic contrast enhanced (DCE) MRI pharmacokinetic modelling. We investigate effects of altering VIF CA bolus arrival delays on liver DCE MRI perfusion parameters, propose an alternative approach to estimating delays and evaluate reproducibility. Thirteen healthy v...

متن کامل

Correction of arterial input function in dynamic contrast-enhanced MRI of the liver.

PURPOSE To develop a postprocessing method to correct saturation of arterial input function (AIF) in T1-weighted dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for quantification of hepatic perfusion. MATERIALS AND METHODS The saturated AIF is corrected by parameterizing the first pass of the AIF as a smooth function with a single peak and minimizing a least-squares error in f...

متن کامل

Interest of reference region models to monitor cancer treatment using dynamic contrast enhanced studies

Aim Dynamic Contrast Enhanced (DCE) imaging is an investigative tool to monitor cancer treatments such as antiangiogenic drugs. The difficulty of estimating an appropriate arterial input function in MRI or ultrasound for instance makes the reference region (RR) model very attractive. However it is not applicable to hepatic perfusion studies for which two input functions (hepatic artery and port...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

The influence of cardiac frequency on the properties of the arterial input function (AIF) and computed DCE-MRI parameter values

Introduction: Quantitative determination of tissue perfusion, permeability and blood volume fraction applying DCE-MRI requires knowledge of the arterial plasma concentration of the contrast agent (CA) in the vessels feeding the tissue of interest. This arterial input function (AIF) must be sampled with high temporal and spatial resolution to enable stable pharmacokinetic (PK) modeling [1]. With...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 2017