Development and validation of dissolution method for carvedilol compression-coated tablets
نویسندگان
چکیده
The present study describes the development and validation of a dissolution method for carvedilol compression-coated tablets. Dissolution test was performed using a TDT-06T dissolution apparatus. Based on the physiological conditions of the body, 0.1N hydrochloric acid was used as dissolution medium and release was monitored for 2 hours to verify the immediate release pattern of the drug in acidic pH, followed by pH 6.8 in citric-phosphate buffer for 22 hours, to simulate a sustained release pattern in the intestine. Influences of rotation speed and surfactant concentration in medium were evaluated. Samples were analysed by validated UV visible spectrophotometric method at 286 nm. 1% sodium lauryl sulphate (SLS) was found to be optimum for improving carvedilol solubility in pH 6.8 citric-phosphate buffer. Analysis of variance showed no significant difference between the results obtained at 50 and 100 rpm. The discriminating dissolution method was successfully developed for carvedilol compression-coated tablets. The conditions that allowed dissolution determination were USP type I apparatus at 100 rpm, containing 1000 ml of 0.1N HCl for 2 hours, followed by pH 6.8 citric-phosphate buffer with 1% SLS for 22 hours at 37.0 ± 0.5 oC. Samples were analysed by UV spectrophotometric method and validated as per ICH guidelines.
منابع مشابه
Development and Validation of New Discriminative Dissolution Method for Carvedilol Tablets
The objective of the present study was to develop and validate a discriminative dissolution method for evaluation of carvedilol tablets. Different conditions such as type of dissolution medium, volume of dissolution medium and rotation speed of paddle were evaluated. The best in vitro dissolution profile was obtained using Apparatus II (paddle), 50 rpm, 900 ml of pH 6.8 phosphate buffer as diss...
متن کاملDevelopment and validation of dissolution tests for fexofenadine hydrochloride capsules and coated tablets.
PURPOSE This study describes the development and validation of dissolution tests for fexofenadine hydrochloride capsules and coated tablets using an HPLC method. METHOD The appropriate conditions were determinate after testing sink conditions, dissolution medium, and agitation intensity. The apparatus, paddle and basket, were applied to tablets and capsules, respectively. Fexofenadine hydroch...
متن کاملDesign, Development, and Optimization of Polymeric Based-Colonic Drug Delivery System of Naproxen
The aim of present investigation deals with the development of time-dependent and pH sensitive press-coated tablets for colon specific drug delivery of naproxen. The core tablets were prepared by wet granulation method then press coated with hydroxypropyl cellulose (HPC) or Eudragit RSPO : RLPO mixture and further coated with Eudragit S-100 by dip immerse method. The in vitro drug release study...
متن کاملColon Targeted Guar Gum Compression Coated Tablets of Flurbiprofen: Formulation, Development, and Pharmacokinetics
The rationale of the present study is to formulate flurbiprofen colon targeted compression coated tablets using guar gum to improve the therapeutic efficacy by increasing drug levels in colon, and also to reduce the side effects in upper gastrointestinal tract. Direct compression method was used to prepare flurbiprofen core tablets, and they were compression coated with guar gum. Then the table...
متن کاملThe Effect of Formulation Variables on the Release Kinetics of Paracetamol Tablet Formulations.
Aim: The objective of this work was to study the effects of formulation variables on the release kinetics of paracetamol tablet formulation. Materials and Methods: Paracetamol tablets were formulated using wet granulation (WG) and direct compression (DC) using two predetermined pressures. Avicel, dicalcium phosphate (DCP) and pregelatinized starch (PGS) were used as directly compressible...
متن کامل