Survivorship and relative risk of revision in computer-navigated versus conventional total knee replacement at 8-year follow-up
نویسندگان
چکیده
Background and purpose - The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patients and methods - We assessed primary total knee replacements without patellar resurfacing reported to the Norwegian Arthroplasty Register from 2005 through 2014. The 5 most used implants and the 3 most common navigation systems were included. The groups (CAS, n = 3,665; CON, n = 20,019) were compared using a Cox regression analysis adjusted for age, sex, ASA category, prosthesis brand, fixation method, previous surgery, and diagnosis with the risk of revision for any reason as endpoint. Secondary outcomes were reasons for revision and effects of prosthesis brand, fixation method, age (± 65 years), and hospital volume. Results - Prosthesis survival and risk of revision were similar for CAS and CON. CAS had significantly fewer revisions due to malalignment. Otherwise, no statistically significant difference was found between the groups in analyses of secondary outcomes. Mean operating time was 13 minutes longer in CAS. Interpretation - At 8 years of follow-up, CAS and CON had similar rates of overall revision, but CAS had fewer revisions due to malalignment. According to our findings, the benefits of CAS at medium-term follow-up are limited. Further research may identify subgroups that benefit from CAS, and it should also emphasize patient-reported outcomes.
منابع مشابه
Better Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up
Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship. Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 ...
متن کاملComputer navigation versus conventional total knee replacement: no difference in functional results at two years.
We previously compared the component alignment in total knee replacement using a computer-navigated technique with a conventional jig-based method. We randomly allocated 71 patients to undergo either computer-navigated or conventional replacement. An improved alignment was seen in the computer-navigated group. The patients were then followed up post-operatively for two years, using the Knee Soc...
متن کامل10-Year Survival of Navigated Versus Conventional TKAs: A Retrospective Study.
The computer-assisted navigation of total knee arthroplasty (TKA) offers a radiologically demonstrated higher precision of implantation than conventional implantation in relation to the axis alignment. The impact on long-term clinical outcomes is currently unknown. In 1999, 217 consecutive TKAs were performed in a total of 213 patients (113 navigated and 104 conventional). After 10 years, it wa...
متن کاملRevision total knee arthroplasty: causes and outcomes.
INTRODUCTION Local data on revision total knee arthroplasty (TKA) are limited. This study aims to assess the causes and outcomes of revision TKA in a single institution, with a 2-year follow-up. MATERIALS AND METHODS A retrospective review of case records of patients who underwent revision TKA in 2008 and 2009 in the authors' institution was performed. Outcome was assessed using SF-36, Oxford...
متن کاملColumbus navigated TKA system: clinical and radiological results at a minimum of 5 years with survivorship analysis.
The major factors that determine a favorable long-term clinical and functional outcome after conventional total knee arthroplasty (TKA) include correct implant positioning and restoration of the mechanical axis with soft tissue balancing to reduce aseptic failure; hence, the need for further developmental strategies that improve the accuracy and reproducibility of the surgical technique remains...
متن کامل