Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

نویسندگان

  • S Sivaram Kaushik
  • Matthew S Freeman
  • Zackary I Cleveland
  • John Davies
  • Jane Stiles
  • Rohan S Virgincar
  • Scott H Robertson
  • Mu He
  • Kevin T Kelly
  • W Michael Foster
  • H Page McAdams
  • Bastiaan Driehuys
چکیده

Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P < 0.001). The 129Xe gas-transfer maps also exhibited significant heterogeneity, as measured by the coefficient of variation, that correlated with subject total lung capacity (r = 0.77, P = 0.015). Gas-transfer intensity varied nonmonotonically with slice position and increased in slices proximal to the main pulmonary arteries. Despite substantial heterogeneity, the mean gas transfer for all subjects was 1.00 ± 0.01 while supine and 1.01 ± 0.01 while prone (P = 0.25), indicating good "matching" between gas- and dissolved-phase distributions. This study demonstrates that single-breath gas- and dissolved-phase 129Xe MR imaging yields 129Xe gas-transfer maps that are sensitive to altered gas exchange caused by differences in lung inflation and posture.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans

BACKGROUND One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS Here we exploit the solubility, hig...

متن کامل

Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase Xe MR imaging

S. Sivaram Kaushik, Matthew S. Freeman, Zackary I. Cleveland, John Davies, Jane Stiles, Rohan S. Virgincar, Scott H. Robertson, Mu He, Kevin T. Kelly, W. Michael Foster, H. Page McAdams, and Bastiaan Driehuys Department of Biomedical Engineering, Duke University, Durham, North Carolina; Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina; Graduate Program in Me...

متن کامل

Simultaneous Imaging of Ventilation Distribution and Gas Exchange in the Human Lung using Hyperpolarized Xe129 MRI

Introduction: The high solubility of xenon in biological tissues, combined with an exquisite sensitivity to its environment that results in an enormous range of chemical shifts upon solution, make hyperpolarized Xe129 particularly attractive for exploring characteristics of lung function, such as gas exchange, that are not accessible by using hyperpolarized He3. With improvements in gas-polariz...

متن کامل

In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe

BACKGROUND Hyperpolarized (HP) (129)Xe magnetic resonance imaging (MRI) permits high resolution, regional visualization of pulmonary ventilation. Additionally, its reasonably high solubility (>10%) and large chemical shift range (>200 ppm) in tissues allow HP (129)Xe to serve as a regional probe of pulmonary perfusion and gas transport, when introduced directly into the vasculature. In earlier ...

متن کامل

Development of a hyperpolarized 129Xe system on 3T for the rat lungs.

MRI (magnetic resonance imaging) with 129Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 115 6  شماره 

صفحات  -

تاریخ انتشار 2013