Optimal Zone II flexor tenorraphy

نویسنده

  • M Ibrahim Khan
چکیده

“There is a great difference between knowing and understanding: You can know a lot about something and not really understand it.â€�. This quote attributed to Charles Kettering explains why the more we know about zone 2 repairs; the less we seem to understand. In this presentation, I will show that our lack of understanding is due entirely to biomechanical gaps in the current knowledge—gaps large enough to drive a truck through. Flexor tendon groupthink is turning a blind eye to these gaps partly because of their obsession with the blood supply of the flexor tendon and partly because of the control of their zone 2 vocabulary by the ultimate tensile strength of the repair which has blinded them to the proverbial elephant in the room – dorsal gapping at the repair site and its consequences such as adhesions including PIP flexion contractures and ruptures. This presentation will be all about identifying and closing these gaps. So, the biomechanical sine qua nons of an optimal suture for zone 2 flexor tenorrhaphy are: (1) Non-end placement for optimal loading: State of the art palmer end-placement of the ‘core’ suture and controlled mobilization is a classic case study in unintended biomechanical consequences or U.B.C. Exhibit A is eccentric loading of the flexor tendon, which boomerangs back on the repair site as a negative bending moment with the bending tensile stresses on the dorsum and bending compressive stresses on the palmar side, ripping the repair apart dorsally, resulting in dorsal gap which is exhibit B. This dorsal gap induces instability at the repair site which in turn seduces the tendon sheath to invade the tendon all in the name of stability. If the sheath succeeds, we end up with adhesions including P.I.P. flexion contractures but if it fails the negative consequence will be rupture. What has made the end-placement a case of “out of the frying pan, in to the fire” is the fantasy marriage of this technique and multi strands such as Savage six strand suture and its endless imitations because the powerful one-two punch of palmar end placement and multi strands does not give the suture just a bite on the palmer side but a savage bite, opening the repair dorsally like a book. Since dorsal gap is initiated by the palmar end-placement of the core suture and propagated by controlled mobilization, the question on every one’s mind is: Can the end-placement be made harmless? Theoretically, if the suture can be placed along the centroid of the flexor tendon, then that will take care of the bending moment and make the end-placement harmless. But that’s impractical because the centroid of flexor tendon is a shifting tech tonic plate between fully extended and fully flexed positions of the finger. So, faced with zone 2 repairs’ technical dilemma of either chasing an elusive centroid or making the centroid virtual, it’s a no brainer that we have to make it virtual and that means ‘non-end placement’. (2) Large central loops for optimal load bearing: The amount of load that a suture can bear is directly proportional to the frictional resistance at suture-tendon interface which in turn is dependent on: (a) the size of suture material (b) the size of loops the suture makes in the tendon. (Suture anchoring). But the standardized size of the suture for Zone 2 repairs leaves us with one and only one choice to enhance the load bearing capability of the suture and that is to enlarge the size of the suture loops. So, quite contrary to the current state of the art practice, what is needed is utilization of large loops in the center of the tendon with multi planner obliquities but no locking for enhanced anchoring. (3) Multi strands for optimal tensile strength: A multi strand suture can and will multiply the tensile strength of its strands provided that there’s simultaneous loading Department of Plastic Surgery, DHQ Hospital, Rawalpindi, Pakistan Khan BMC Proceedings 2015, 9(Suppl 3):A67 http://www.biomedcentral.com/1753-6561/9/S3/A67

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional evaluation after primary flexor tendon repair in zone II.

The purpose of this prospective study was to evaluate the results of primary treatment of flexor tendon laceration in zone II according to Verdan's zone system. Special emphasis was given to the postoperative rehabilitation program. Nineteen patients (23 fingers) with laceration of the flexor tendons in zone II were treated operatively. Twelve males and seven females were included in the study....

متن کامل

Physical Therapy and Splinting After Flexor Tendon Repair in Zone II

INTRODUCTION Early physical therapy and splinting after flexor tendon repair in zone II is very important to improve tendon healing, increase tensile strength, decrease adhesion formation, early return of function and less stiffness and deformity. We conducted a study to observe and record the results of early active mobilization of repaired flexor tendons in zone II. MATERIALS AND METHOD Thi...

متن کامل

Pediatric flexor tendon injuries: A 10-year outcome analysis.

BACKGROUND Primary flexor tendon repair was first introduced in the 1960s. Since then, major advances in the understanding of flexor tendon anatomy and biology have led to improved outcomes following repair. Relative to the adult population, sparse knowledge exists as to which operative and postoperative treatments are most successful in children. This is due, in part, to the rarity of pediatri...

متن کامل

Abstract: A Comparison of Epitendinous Repair Techniques for Flexor Tenorraphy

METHODS: Phalloplasty aesthetic subunits were defined and subunit measurements and ratios were examined. A split testing-based questionnaire was distributed to medical personnel and online forum users to determine the preferred aesthetic ideals based on phallic subunits. Digitally-altered photos focusing on varying ratios of the shaft, glans, corona, and frenulum were presented to participants ...

متن کامل

Flexor Digitorum Superficialis and Flexor Digitorum Profundus with separated sheaths

CASE DESCRIPTION A 25 years old man presented with a laceration on radial side of proximal phalanx of 4(th) finger (zone II flexor) which was due to cut with glass. CLINICAL FINDINGS The sheaths of Tendons of flexor digitorum superficialis and profundus were not the same and each tendon had a separate sheath. TREATMENT AND OUTCOME The tendons were reconstructed by modified Kessler sutures, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015