Automated Optic Nerve Disc Parameterization

نویسندگان

  • Povilas Treigys
  • Vydunas Saltenis
  • Gintautas Dzemyda
  • Valerijus Barzdziukas
  • Alvydas Paunksnis
چکیده

New information technologies provide a possibility of collecting a large amount of fundus images into databases. It allows us to use automated processing and classification of images for clinical decisions. Automated localization and parameterization of the optic nerve disc is particularly important in making a diagnosis of glaucoma, because the main symptoms in these cases are relations between the optic nerve and cupping parameters. This article describes the automated algorithm for the optic nerve disc localization and parameterization by an ellipse within colour retinal images. The testing results are discussed as well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Optic Nerve Disc and Excavation Parameters of Interactive and Automated Parameterization Methods

Glaucoma is one of the most insidious eye diseases the occurrence and progression of which a human does not feel. This article provides a brief overview of the eye nerve parameterization methods and algorithms. Parameterization itself is an important task that provides and uniquely defines the structure of the optic nerve disc and further can be used in disease detection or other studies that r...

متن کامل

Automated Interpretation of Optic Nerve Images: A Data Mining Framework for Glaucoma Diagnostic Support

Confocal Scanning Laser Tomography (CSLT) techniques capture high-quality images of the optic disc (the retinal region where the optic nerve exits the eye) that are used in the diagnosis and monitoring of glaucoma. We present a hybrid framework, combining image processing and data mining methods, to support the interpretation of CSLT optic nerve images. Our framework features (a) Zernike moment...

متن کامل

Automated volumetric evaluation of stereoscopic disc photography

PURPOSE To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS One hundred twenty-two stereoscopic optic disc pho...

متن کامل

Local Binary Patterns and Modified Red Channel for Optic Disc Segmentation

Glaucoma is one of the ocular eye diseases that can cause gradual vision loss and permanent blindness if it is not treated in the early stage. Current screening test such as intraocular pressure (IOP) assessment is not efficient since eye pressure is not the only symptom of glaucoma. The most suitable assessment of the glaucoma is by analyzing the health of the optic nerve head. In order to qua...

متن کامل

Anterior Ischemic Optic Neuropathy Associated with Udenafil

We report a case of anterior ischemic optic neuropathy associated with udenafil. A 54-year-old male presented with an acute onset visual field defect of the right eye after udenafil use. Examination revealed a relative afferent pupillary defect and a swollen disc. Automated visual fields revealed an enlarged blind spot and a narrowed visual field. Fluorescein angiography revealed both an inferi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Informatica, Lith. Acad. Sci.

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2008