Long-term effects of dual-chamber pacing with periodic echocardiographic evaluation of optimal atrioventricular delay in patients with hypertrophic cardiomyopathy >50 years of age.

نویسندگان

  • Ian Topilski
  • Jack Sherez
  • Gad Keren
  • Itzchak Copperman
چکیده

Various treatment modalities have been introduced to reduce the subaortic pressure gradient in patients with obstructive hypertrophic cardiomyopathy, including pacemaker insertion. Complete ventricular capture during pacing is essential and requires optimization of the atrioventricular interval (AVI). In this study, a protocol using echocardiographic examination assessing the changes in the left ventricular outflow tract (LVOT) gradient in different AVIs, pacing rates, and pacing modes was used for optimal pacemaker programming. Twenty-five patients with obstructive hypertrophic cardiomyopathy were implanted with DDD pacemakers and evaluated prospectively. The LVOT gradient was measured during periodic evaluations every 3 to 6 months. Gradient measurements were done with 5 different AVIs and 3 different rate combinations. After each evaluation, the optimal AVI, pacing rate, and mode were set on the basis of the minimal LVOT gradient not associated with systolic arterial cuff pressure reduction. Follow-up ranged from 18 to 126 months. Peak LVOT gradient immediately decreased in 92% of patients. During follow-up, the optimal AVI was prolonged in most patients. Sixty-four percent of patients showed a clear relation between pacemaker modifications and gradient reduction. In 75% of these patients, optimal gradient reduction required repeated AVI and pacing rate programming on the basis of echocardiographic evaluation. Symptoms decreased in 92% of patients, and New York Heart Association class improved significantly (3.1+/-0.7 vs 1.3+/-0.4, p<0.001) during follow-up. The symptomatic reduction was positively correlated with the LVOT gradient reduction. In conclusion, DDD pacing is effective in reducing the LVOT gradient and improving functional capacity in adult patients with hypertrophic cardiomyopathy. Pacemaker programming with the periodic echocardiographic evaluation of the optimal AVI, pacing rate, and mode is imperative for optimal results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term follow-up impact of dual-chamber pacing on patients with hypertrophic obstructive cardiomyopathy.

BACKGROUND Pacing has been proposed as a treatment for patients with hypertrophic obstructive cardiomyopathy (HOCM), but there are few studies with long-term follow-up. We evaluated the long-term effects of dual-chamber pacing therapy for patients with HOCM, and to identify the most prognosis-specific factors for predicting outcome in such treating methods. METHODS A total of 37 HOCM patients...

متن کامل

Ventricular evoked response in patients with hypertrophic obstructive cardiomyopathy treated with DDD pacing.

OBJECTIVE To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the ...

متن کامل

Effects of dual-chamber pacing on regional myocardial deformation in patients with hypertrophic obstructive cardiomyopathy.

BACKGROUND This study examined the effects of dual-chamber pacing (DDD) on regional myocardial deformation, as determined by echocardiographic strain and strain rate (SR) imaging, in patients with hypertrophic obstructive cardiomyopathy (HOCM). METHODS AND RESULTS Fourteen patients (11 men, 3 women; mean age 55 +/-16 years) who had been on long-term DDD (mean period 7.4 +/- 2.1 years) underwe...

متن کامل

Dual Chamber Pacing in a Patient of Hypertrophic Cardiomyopathy with Failure to Wean from Mechanical Ventilator

We discuss the case of a 63 years old female who required repeated intubation due to recurrent pulmonary edema. She was found to have hypertrophic cardiomyopathy with a gradient of 82 mmHg across the left ventricular outflow tract. Initially adequate rate control and treatment with negative inotropes did not help her condition. Finally a dual chamber pacemaker implantation and atrioventricular ...

متن کامل

Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.

An optimized atrioventricular (AV) interval can maximize the benefits of cardiac resynchronization therapy (CRT). If programmed poorly, it may curtail beneficial effects of CRT. AV optimization will not convert non-responder to responder, but may convert under-responder to improved status. There are many echocardiographic techniques for AV optimization but there is no universally accepted gold ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of cardiology

دوره 97 12  شماره 

صفحات  -

تاریخ انتشار 2006