Accuracy of immunoblotting assay for detection of specific IgE compared with ImmunoCAP in allergic patients

نویسندگان

  • Raheleh Shokouhi Shoormasti
  • Mohammad Reza Fazlollahi
  • Anoshirvan Kazemnejad
  • Masoud Movahedi
  • Behnoosh Tayebi
  • Zahra Yazdanyar
  • Zakieh Azadi
  • Zahra Pourpak
  • Mostafa Moin
چکیده

Background and aim Standardized techniques help us to better diagnosis and follow up of allergic diseases. In this study, we determined the sensitivity, accuracy, and specificity of an Immunoblotting test compared to ImmunoCAP as the reference in vitro test for detection of specific IgE in allergic patients. Methods In this cross-sectional study, specific IgE level was determined in patients with allergic symptoms who referred to the Immunology, Asthma and Allergy Research Institute, Tehran, Iran from 2010-2016, by two techniques. Eleven different allergens (six aeroallergens and five food allergens) were determined, and 303 specific IgE tests were performed for the patients by each method. The Immunoblotting test is a multiplex assay on a nitrocellulose membrane coated with 20 selected allergens. ImmunoCAP is considered as the reference method for determination of in vitro specific IgE. Its principle is an automated sandwich immunoassay, and allergens were bound to the solid phase, covalently. Finally, the fluorescence of elute was determined. Specific IgE more than 0.35 KU/L was considered as a positive test. Sensitivity, specificity, accuracy, kappa coefficient, positive and negative likelihood ratio (+/- LR), and correlation coefficient (calculated with Spearman test) between two tests were determined using statistical analysis (SPSS software, version 18). Results One hundred and thirty five patients entered this study. The median age of the patients was 3.75 years with the males constituting 54.8% of the population. The most common cheif complaints were respiratory (51.6%), skin (41.8%) and gastrointestinal (27.9%) symptoms, respectively. The sensitivity, specificity, accuracy, +LR and -LR were 83%, 97%, 92%, 27.66 and 0.17, respectively. The kappa coefficient of the immunoblotting test was 0.81 compared to the reference technique. The correlation coefficient for positive tests between the two methods was 0.71 (p<0.001). Conclusion Regarding the presence of 20 allergens in a RIDA allergy panel and according to our findings, this immunoblotting test with high sensitivity could be used as a fast and cost-efficient screening test. However, ImmunoCAP is recommended when the accurate level of specific IgE is required. ImmunoCAP findings are particularly helpful for immunotherapy and the elimination diet.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of specific IgE detection by immunoblotting and fluorescence enzyme assay with in vivo skin prick test.

BACKGROUND Diagnostic tools to identify allergens that cause allergic symptom is important part in the care of allergic patients. Detection of causative allergen can be performed by in vivo skin prick test (SPT) or in vitro tests for detection serum specific immunoglobulin E (sIgE). The common methods used are fluorescent enzyme assay and immunoblotting assay. OBJECTIVE We aim to evaluate per...

متن کامل

Comparison of the ImmunoCAP Assay and AdvanSure™ AlloScreen Advanced Multiplex Specific IgE Detection Assay

PURPOSE The AdvanSure™ AlloScreen assay is an advanced multiplex test that allows for simultaneous detection of specific IgE (sIgE) against multiple allergens. For precise identification of causative allergens in allergic patients, we compared this new multiplex sIgE assay with the ImmunoCAP assay, which is currently the gold-standard method for sIgE detection. MATERIALS AND METHODS Serum sam...

متن کامل

Evaluation of a Novel Rapid Test System for the Detection of Specific IgE to Hymenoptera Venoms

Background. The Allergy Lateral Flow Assay (ALFA) is a novel rapid assay for the detection of sIgE to allergens. The objective of this study is the evaluation of ALFA for the detection of sIgE to bee venom (BV) and wasp venom (WV) in insect venom allergic patients. Methods. Specific IgE to BV and WV was analyzed by ALFA, ALLERG-O-LIQ, and ImmunoCAP in 80 insect venom allergic patients and 60 co...

متن کامل

Performance of the PROTIA™ Allergy-Q® System in the Detection of Allergen-specific IgE: A Comparison With the ImmunoCAP® System

PURPOSE The PROTIA™ Allergy-Q® enzyme immunoassay (EIA) is a recently developed screening assay for specific immunoglobulin E (sIgE) for multiple allergens. The ImmunoCAP® fluorescent EIA (FEIA) system is the most widely used method for sIgE detection. In this study, we evaluated the performance of the Allergy-Q® system compared to the ImmunoCAP® system. METHODS We compared the 2 systems usin...

متن کامل

Increased allergen-specific IgG4 levels are linked to suppressed IgE titers when analysed by ISAC but not by immunocap

Allergen specific immunotherapy (ASIT) is the only disease modifying treatment of allergic diseases. A key element in the protective effect is thought to be induction of a specific IgG4 response leading to a decrease in the IgE-mediated allergic symptoms. The effect of ASIT can be ascertained by provocation or skin prick testing. IgE measurement by ImmunoCAP is a sensitive standard procedure fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018