Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images.
نویسندگان
چکیده
BACKGROUND For the investigation of the molecular mechanisms involved in neurite outgrowth and differentiation, accurate and reproducible segmentation and quantification of neuronal processes are a prerequisite. To facilitate this task, we developed a semiautomatic neurite tracing technique. This article describes the design and validation of the technique. METHODS The technique was compared to fully manual delineation. Four observers repeatedly traced selected neurites in 20 fluorescence microscopy images of cells in culture, using both methods. Accuracy and reproducibility were determined by comparing the tracings to high-resolution reference tracings, using two error measures. Labor intensiveness was measured in numbers of mouse clicks required. The significance of the results was determined by a Student t-test and by analysis of variance. RESULTS Both methods slightly underestimated the true neurite length, but the differences were not unanimously significant. The average deviation from the true neurite centerline was a factor 2.6 smaller with the developed technique compared to fully manual tracing. Intraobserver variability in the respective measures was reduced by a factor 6.0 and 23.2. Interobserver variability was reduced by a factor 2.4 and 8.8, respectively, and labor intensiveness by a factor 3.3. CONCLUSIONS Providing similar accuracy in measuring neurite length, significantly improved accuracy in neurite centerline extraction, and significantly improved reproducibility and reduced labor intensiveness, the developed technique may replace fully manual tracing methods.
منابع مشابه
NeuriteTracer: a novel ImageJ plugin for automated quantification of neurite outgrowth.
In vitro assays to measure neuronal growth are a fundamental tool used by many neurobiologists studying neuronal development and regeneration. The quantification of these assays requires accurate measurements of neurite length and neuronal cell numbers in neuronal cultures. Generally, these measurements are obtained through labor-intensive manual or semi-manual tracing of images. To automate th...
متن کاملAutomated neurite labeling and analysis in fluorescence microscopy images.
BACKGROUND To investigate the intricate nervous processes involved in many biological activities by computerized image analysis, accurate and reproducible labeling and measurement of neurites are prerequisite. We have developed an automated neurite analysis method to assist this task. METHODS Our approach can be considered as automated with certain user interaction in setting initial paramete...
متن کاملA Novel Approach to Neurite Tracing in Fluorescence Microscopy Images
In this paper we propose a new, interactive technique for the segmentation of elongated structures in images. It is based on the so-called live-wire segmentation paradigm and uses a newly developed steerable filter for computing local ridge strength and orientation. We describe the principles of our segmentation technique and present the results of preliminary experiments demonstrating its pote...
متن کاملValidation and reliability study of a ventilator usability assessment tool
Abstract Background: Usability is an index to assess a product from the viewpoint of users satisfaction, efficiency and productivity improvement. The main attributes of usability that are derived from the human factors are and used in usability design of the interfaces Include: compatibility, consistency, flexibility, minimal action, perceptual limitation, usefulness, learnability, ease of u...
متن کاملDesign and validation of a tool for measuring knowledge, attitude and practice (KAP) regarding chemical safety in laboratory
ABSTRACT Due to the increasing use of chemicals in academic laboratories, a tool to measure awareness of students regarding labeling, hazards and characteristics of chemicals is still needed. The aim of this study was to design and validate a questionnaire to the assessing student’s knowledge about chemical hazards. The present study was conducted in two stages of design and evaluation of val...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 58 2 شماره
صفحات -
تاریخ انتشار 2004