IMPORTANCE Fundus albipunctatus (FA) is a form of congenital stationary night blindness characterized by yellow-white spots, which were classically described as subretinal. Although night blindness and delayed dark adaptation are hallmarks of this condition, recent studies have described a macular phenotype, particularly among older patients. Using a fluorescence adaptive optics scanning laser ophthalmoscope (FAOSLO), this study provides in vivo morphologic data at the cellular level in FA. OBJECTIVE To study the cone photoreceptors and the albipunctate spots in FA at single-cell resolution. DESIGN, SETTING, AND PARTICIPANT A woman in her 30s with FA underwent a complete ophthalmic examination, including conventional imaging tests, at the University of Rochester. A FAOSLO was used to obtain infrared reflectance images of the cone mosaic at the central fovea and along the superior and temporal meridians to 10° eccentricity. Cone density was measured at the foveal center, and cone spacing was calculated in sampling windows eccentrically. In the area of the albipunctate spots, autofluorescence FAOSLO images (excitation, 561 nm; emission, 624 Δ 40 nm) were simultaneously obtained. MAIN OUTCOMES AND MEASURES Structural appearance of cones, cone density and spacing, and reflectance and autofluorescence of albipunctate spots. RESULTS Cone density was reduced to 70% of the lower limit of the normal range at the foveal center (78.7 × 10(3) cones/mm(2); mean [SD] reference range, 199 [87] × 10(3) cones/mm(2)), and cone spacing was increased eccentrically to 10° (sign test, P = .045). Individual cone central core reflectances appeared dim, suggesting loss of photoreceptor outer segments. The albipunctate spots were hypoautofluorescent. No photoreceptors or retinal pigment epithelium cells were identified at the locations of the albipunctate spots. CONCLUSIONS AND RELEVANCE Although the predominant clinical symptom of night blindness and the electroretinography results suggest a primary rod dysfunction, examination with a FAOSLO demonstrates that cone density is also reduced. This finding may represent an early sign of progression to macular phenotype in FA. The hypoautofluorescence suggests that the albipunctate spots do not represent lipofuscin.
منابع مشابه
High-resolution retinal imaging of cone-rod dystrophy.
PURPOSE This study examines a patient with cone-rod dystrophy using high-resolution adaptive optics retinal imaging. Conventional ophthalmoscopes provide limited resolution due to their inability to overcome the eye's optical aberrations. In contrast, adaptive optics ophthalmoscopes correct these aberrations to provide noninvasive high-resolution views of the living retina. To date, adaptive op...
متن کاملObservation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope
We demonstrate the capability of a new generation adaptive optics scanning laser ophthalmoscope (AOSLO) to resolve cones and rods in normal subjects, and confirm our findings by comparing cone and rod spacing with published histology measurements. Cone and rod spacing measurements are also performed on AOSLO images from two different diseased eyes, one affected by achromatopsia and the other by...
متن کاملRetinal Damage in Chloroquine Maculopathy, Revealed by High Resolution Imaging: A Case Report Utilizing Adaptive Optics Scanning Laser Ophthalmoscopy
A 53-year-old Asian woman was treated with hydroxychloroquine and chloroquine for lupus erythematosus. Within a few years, she noticed circle-shaped shadows in her central vision. Upon examination, the patient's visual acuity was 20 / 25 in both eyes. Humphrey visual field (HVF) testing revealed a central visual defect, and fundoscopy showed a ring-shaped area of parafoveal retinal pigment epit...
متن کاملDysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis
PURPOSE Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. METHODS A patient...
متن کاملSpectrally encoded confocal scanning laser ophthalmoscopy.
We present in vivo human fundus imaging using a fiber-based confocal scanning laser ophthalmoscope (SLO). Spectrally encoded confocal scanning laser ophthalmoscopy (SECSLO) utilizes a spectral encoding technique in one dimension, combined with single-axis lateral scanning, to create video-rate reflectivity maps of the fundus. This implementation of the SLO allows for high-contrast high-resoluti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA ophthalmology
دوره 132 9 شماره
صفحات -
تاریخ انتشار 2014