Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen
نویسندگان
چکیده
BACKGROUND Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). OBJECTIVES We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. PATIENTS AND METHODS Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. RESULTS Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. CONCLUSIONS The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients.
منابع مشابه
Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study
Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...
متن کاملSplit-bolus versus triphasic multidetector-row computed tomography technique in the diagnosis of hepatic focal nodular hyperplasia: a case report
INTRODUCTION Computed tomography and magnetic resonance imaging are able to demonstrate and to diagnose hepatic focal nodular hyperplasia when a typical pattern of a well-circumscribed lesion with a central scar is present.Our aim is to propose the split-bolus multidetector-row computed tomography technique as an alternative to the conventional triphasic technique in the detection and character...
متن کاملDetection and characterization of focal liver lesions by split-bolus multidetector-row CT: diagnostic accuracy and radiation dose in oncologic patients.
AIM To assess the diagnostic accuracy and radiation dose of split-bolus multidetector-row computed tomography (MDCT) protocol in the detection and characterization of focal liver lesions in oncologic patients. PATIENTS AND METHODS We retrospectively analyzed triphasic CT at initial diagnosis and follow-up split-bolus 64-detector row CT protocol in 48 oncologic patients with focal liver lesion...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملOptimal scan delay depending on contrast material injection duration in abdominal multi-phase computed tomography of pancreas and liver in normal Beagle dogs
This study was conducted to establish the values for optimal fixed scan delays and diagnostic scan delays associated with the bolus-tracking technique using various contrast material injection durations in canine abdominal multi-phase computed tomography (CT). This study consisted of two experiments employing the crossover method. In experiment 1, three dynamic scans at the porta hepatis were p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2014