SU-E-T-21: Modeling a MLC Scatter Source for In-Air Output Factors.

نویسندگان

  • S Park
  • S Kim
  • Y Park
  • J Park
  • J Kim
  • H Kim
  • C Choi
  • S Ye
چکیده

PURPOSE Scattered radiation from multi-leaf collimators (MLCs) is no longer negligible for calculating in-air output ratio, Sc for small and irregular fields often used in intensity-modulated radiation therapy (IMRT). An extra-focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. METHODS A conventional dual-source model was made by using Sc data that were measured for collimator-defined fields of Varian Clinac IX linear accelerator. Then, an MLC scatter source at the center of the MLC position of the linear accelerator was assumed in the model. The MLC scatter source model consisted of two Gaussian functions of which parameters were iteratively optimized against the Sc data measured for different MLC fields with fixed collimator sizes. To evaluate the effectiveness of the developed source model, measurements were made for various MLC-defined irregular or square fields. The calculated Sc data by using (1) the developed source model and (2) the conventional dual source model were compared with the measured data. RESULTS The mean discrepancy between the measured Sc and calculated Sc from the developed source model was 0.08+-0.28%, while one from the conventional source model was 0.44+-0.39%. CONCLUSIONS The developed MLC scatter source model in conjunction with the dual source model could improve the accuracy of the Sc calculation in IMRT fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

متن کامل

Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions

Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...

متن کامل

Beam characteristic of P.E collimators Add-on multileaf collimator

  Introduction:    Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the ...

متن کامل

Interpretation of in-air output ratio and its impact on Dose Calculation

The concept of in-air output ratio (Sc) was introduced to characterize how the incident photon fluence per monitor unit (or unit time for a Co-60 unit) varies with collimator settings. 2 This quantity is also called inair output factor, collimator-scatter factor, and headscatter factor. 6 The latter two names were somewhat misleading since they emphasized a single component of the output ratio....

متن کامل

Modeling of Atmospheric Regional Circulation for Event of Most Severe Spring Dust Storms on West of Iran

   Dust phenomenon is a natural occurrence that occurs widespread in arid and semi-arid regions of the world, especially in the sub-equatorial latitudes. This phenomenon is among the greatest environmental problems in the world. The release of this destructive climatic phenomenon in a scattered manner in the atmosphere varies in size, time and concentration. Since this phenomenon is influenced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part9  شماره 

صفحات  -

تاریخ انتشار 2012