Reply to "Letter to the editor: Angiotensin quantification by mass spectrometry".
نویسنده
چکیده
REPLY: Although I appreciate the comments from Poglitsch and colleagues in their letter (5), their assertion that my review concluded that liquid chromatography-mass spectrometry (LCMS) lacks the sensitivity to quantify endogenous angiotensins and requires exogenous renin for peptide detection is surprising and quite incorrect. I discussed multiple LC-MS studies that quantified angiotensins in plasma and tissues in the sensitivity range of immunoassays (RIA, ELISA) without the addition of renin that included their own LC-MS analysis of mouse plasma and kidney (1, 2, 6). In fact, their ANG II and ANG III values for mouse kidney were included in Table 1 of the review article that describes a validated range of values for angiotensins in plasma, tissues, urine, and cells (1, 2). Perhaps their misunderstanding arose from my comment on Dr. Poglitsch’s quantitation of plasma ANG II by LC-MS in which they added exogenous renin to human plasma (3, 4). I noted that these data were not comparable with those of other MS or RIA studies and that because of the renin addition, the peptide values do not reflect endogenous angiotensins in human plasma (2). Thus it is also surprising that their letter fails to take this opportunity to explain the rationale for addition of exogenous renin to human plasma samples. The other issues presented in the letter concerning assay sensitivity, sample handling, assessment of recovery, and extraction methods were extensively discussed in my review and cite the same set of references included in the review. I also stated that Dr. Poglitsch provides a commercial LC-MS service (MS-fingerprint, Attoquant) with the capability to quantify 10 angiotensins including ANG I, ANG II, and ANG-(1-7) in a single sample at a sensitivity or detection limit of RIA (2). An important aspect of this service is the potential as a reference laboratory to accurately quantify angiotensins among various tissues and across multiple species, as well as to expand the detection of peptide isoforms beyond the antibodybased RIA or ELISA methods. However, I would urge that the methods used in this particular approach be more transparent (i.e., identity and concentration of the inhibitors used in sample collection, sequence of standards added, sampling handling without addition of renin as standard procedure, extraction techniques) such that a more thorough assessment of the LC-MS method and the resultant data can occur. As a case in point, LC-MS by Dr. Poglitsch revealed a very high plasma ratio of ANG III to ANG II that may manifest from incomplete inhibition of ex vivo sample processing rather than a valid profile of these peptides in the circulation of both female and male mice (6). My review concluded, in part, that current LC-MS methods that quantify angiotensins and the peptide values reported in the literature are not consistent at this time. This reflects that fact that several published LC-MS studies report plasma or tissue peptide values that are 100to 1,000-fold higher and often with a higher ratio of ANG II metabolites to the ANG II parent peptide than LC-RIA or other LC-MS studies where the sample collection and extraction techniques are well documented and appropriate (2). Lastly, recognition of accepted values of angiotensin peptides in various biological compartments facilitates our ability to judge optimal methods of quantitation, as well as assess valid alterations in the peptide components of the renin-angiotensin system (2).
منابع مشابه
Comment to the Letter to the Editor: Subjective Symptoms Related to GSM Radiation from Mobile Phone Base Stations: a cross-sectional study In reply to the comments by Seyed Mohammad Javad Mortazavi
متن کامل
Letter to the editor: Angiotensin quantification by mass spectrometry.
TO THE EDITOR: With great interest, we have read Mark Chappell’s (4) comprehensive overview on molecular components of the renin-angiotensin system (RAS). It focused on the analytical methods that can be used to determine the activity or concentration of these molecules, with special emphasis on RIA and ELISA. We fully agree that the sampling procedure is critical to obtain reliable data on ang...
متن کاملIncreased Risk of Kidney Disorders in Patients with Coronavirus 2019: A Letter to the Editor
Background and Objectives: Coronavirus 2019 (Covid-19) has become a global disease that can affect various organs of the human body. Kidney disorders are the most common disorders in patients with Covid-19. Kidney involvement manifests as proteinuria and acute kidney injury (AKI). This virus can cause acute tubular necrosis, protein leakage in the Bowman's capsule, glomerulopathy, and mitochond...
متن کاملEnvironmental gamma radiation: a comment (Letter to the Editor)
Editor, I read the recent publication by Toossi et al. with a great interest (1). Toossi et al. concluded that “Average gonad and bone marrow doses for North Khorasan, Boshehr and Hormozgan provinces were less than the corresponding values for normal area (2).” There are some facts on this report to be concerned. I agree that the detected levels might be high in the mentioned area, but th...
متن کاملLetter to editor
Dear Prof. Mozdarani,I would like to discuss about some important aspects regarding the article published in, "Iran. J. Radiat. Res., 2012 10(2): 89-94“ with title of “Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode" by Ghavami et al. (1), so according to journal policy and in suitable manner please ask the authors to rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 310 3 شماره
صفحات -
تاریخ انتشار 2016