Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery
نویسندگان
چکیده
BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinical study was conducted between February and September 2011 on 30 eyes divided into four groups, i.e. 20 corneas of 10 patients before LASIK (group A), 20 corneas of the same patients 2 months postoperatively (group B), 10 corneas of five patients before Epi-LASIK (group C), and 10 corneas of the same patients 2 months postoperatively (group D). Patient age ranged from 20 to 50 years. IOP was measured using Goldmann applanation and air puff tonometry, ORA corneal compensation, and Pentacam correction (which also measured central corneal thickness). RESULTS Significant positive linear correlations were found between IOP values measured by Goldmann applanation tonometry and other techniques, and with preoperative pachymetry in group A. The correlation between preoperative Pentacam-corrected and preoperative ORA corneal-compensated IOP was strongest for Goldmann applanation tonometry (r = 0.97 and r = 0.858 respectively, P < 0.001). Compared with preoperative values, postoperative IOP measured by the four methods were significantly lower. The difference was statistically significant when IOP was measured using Goldmann applanation and air puff tonometry compared with the ORA and Pentacam methods (P < 0.001 for LASIK patients and P = 0.017 for Epi-LASIK patients). Nonsignificant correlations were found between the degree of lowering of postoperative IOP and postoperative pachymetry in groups B and D. CONCLUSION Refractive surgery causes significant lowering of IOP as measured using Goldmann applanation tonometry, air puff tonometry, ORA compensation, and Pentacam correction. LASIK has a greater effect than Epi-LASIK on IOP measurement error following refractive surgery.
منابع مشابه
Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملGraft Biomechanics Following Three Corneal Transplantation Techniques
PURPOSE To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 e...
متن کاملEffects of concomitant administration of latanoprost and pilocarpine on the intraocular pressure of experimentally glaucomatous rabbits
The purpose of this study was to evaluate the effects of a combination of latanoprost and pilocarpine onthe intraocular pressure in experimentally glaucomatous rabbits. Ocular hypertension was induced in 11conscious rabbits by the oral administration of tap water (70 mL/kg) via an orogastric tube. The study wasconducted in three therapeutic groups to test the effects of latanoprost (group L), p...
متن کاملEffect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)
Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...