Enhanced ectasia screening: the need for advanced and objective data.
نویسندگان
چکیده
To the Editor: We read with interest the report from Drs. Abdulmassih-Gonçalves and Gonçalves.1 The authors should be commended for publishing a case of ectasia after LASIK, which was detected and addressed by collagen cross-linking. We also appreciate their willingness in sharing the preoperative raw data from rotatingScheimpflug tomography, which generated interesting information that we address in this letter. The tomography examination was taken by the Oculyzer (Wavelight, Inc., Erlangen, Germany), which has the same hardware characteristics as the Oculus Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany). Although the Oculyzer software is designed for topography-guided ablations with the Wavelight excimer lasers, there are significant differences on diagnostic parameters when compared to Pentacam. Objective tomographic parameters, which go beyond curvature and central corneal thickness, are critical for clinical decisions when screening for ectasia risk after laser vision correction.2 Advanced analysis from the raw data generated by the Oculyzer allowed for the calculation of Ambrósio’s Relational Thickness3 and the deviation value from the Belin-Ambrósio Enhanced Ectasia Display (BAD-D), which demonstrates enhanced accuracy for detecting milder forms of ectasia, defined as the fellow eye with relatively normal curvature maps from patients with asymmetric keratoconus (considered as forme fruste keratoconus) (Figure 1).4 BAD-D in the right eye was higher than 1.22, the cut-off value for forme fruste keratoconus (93.62% sensitivity and 94.56% specificity).4 Ambrósio’s Relational Thickness average was lower than 521 μm in both eyes, the cut-off value for forme fruste keratoconus (91.94% sensitivity and 93.05 specificity).4 Ambrósio’s Relational Thickness maximum in the right eye was lower than 386 μm, the cut-off for keratoconus detection (99.17% sensitivity and 97.28% specificity).4 The patient was 21 years old at the time of the Oculyzer examination. Therefore, the Ectasia Risk Score System should be recalculated to 5 for the right eye and 4 for the left eye. Although the consideration of age may be an important factor for the lack of specificity of the Ectasia Risk Score System, there is compelling evidence that supports the younger age being related to lower biomechanical properties of the cornea.2 In a retrospective study involving preoperative clinical and Pentacam data from 23 cases that developed ectasia after LASIK and 266 stable LASIK cases (more than 12 months of follow-up), age was a strong predictor of ectasia risk, being combined in a stepwise logistic regression analysis with BAD-D and residual stromal bed to calculate the Ectasia Susceptibility Score-1. The Ectasia Susceptibility Score-1 represents the percentage of risk for developing ectasia, with a threshold of 6.45%. This allows for 100% sensitivity and 94% specificity, which is better than BAD-D, the best isolated parameter with a cut-off of 1.29 (87% sensitivity and 92.1% specificity).5 Considering the calculated residual stromal bed of 281 and 301 μm,1 the Ectasia Susceptibility Score-1 would be 96.75% and 79% for the right and left eye, respectively. Also, minimal re-
منابع مشابه
Planning and Developing Services for Diabetic Retinopathy in Sub-Saharan Africa
Background Over the past few decades diabetes has emerged as an important non-communicable disease in SubSaharan Africa (SSA). Sight loss from Diabetic Retinopathy (DR) can be prevented with screening and early treatment. The objective of this paper is to outline the required actions and considerations in the planning and development of DR screening services. Methods A multiple-case study app...
متن کاملApplication of Rough Set Theory in Data Mining for Decision Support Systems (DSSs)
Decision support systems (DSSs) are prevalent information systems for decision making in many competitive business environments. In a DSS, decision making process is intimately related to some factors which determine the quality of information systems and their related products. Traditional approaches to data analysis usually cannot be implemented in sophisticated Companies, where managers ne...
متن کاملاستفاده از روش کاپیلاری الکتروفورز جهت غربالگری اختلالات هموگلوبینی شایع در ایران
Hemoglobinopathies are most common inherited disorders in the world; approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. The hemoglobin disorders inherit as autosomal recessive and are very common in the Mediterranean area and much of the Asia and Africa. The control of this inherited disorders need to genetic counseling and accurate screening...
متن کاملRate of ectasia and incidence of irregular topography in patients with unidentified preoperative risk factors undergoing femtosecond laser-assisted LASIK
PURPOSE To report the rate of postoperative ectasia after laser-assisted in situ keratomileusis (LASIK) with femtosecond laser-assisted flap creation, in a population of patients with no identified preoperative risk factors. METHODS A retrospective case review of 1,992 eyes (1,364 patients) treated between March 2007 and January 2009 was conducted, with a follow up of over 4 years. After iden...
متن کاملSimultaneous high hydrogen content-synthesis gas production and in-situ CO2 removal via sorption-enhanced reaction process: modeling, sensitivity analysis and multi-objective optimization using NSGA-II algorithm
The main focus of this study is improvement of the steam-methane reforming (SMR) process by in-situ CO2 removal to produce high hydrogen content synthesis gas. Sorption-enhanced (SE) concept is applied to improve process performance. In the proposed structure, the solid phase CO2 adsorbents and pre-reformed gas stream are introduced to a gas-flowing solids-fixed bed reactor (GFSFBR). One dimens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 30 3 شماره
صفحات -
تاریخ انتشار 2014