Validation of a method for predicting the precision, limit of detection and range of quantitation in competitive ELISA.

نویسندگان

  • Dong Hwan Choi
  • Yoshio Katakura
  • Rieko Matsuda
  • Yuzuru Hayashi
  • Masato Hirobe
  • Yasuhiro Goda
  • Kazuaki Ninomiya
  • Suteaki Shioya
چکیده

The mathematical model for predicting the precision, limit of detection (LOD) and range of quantitation (ROQ) in a competitive enzyme-linked immunosorbent assay (ELISA) proposed by Hayashi et al. (Anal. Chem., 2004, 76, 1295) was validated. The model describes the relative standard deviation (RSD) of concentration estimates by the RSDs of pipetting volumes of analyte, enzyme-conjugated antigen, antibody and substrate solutions, and the standard deviation (SD) of inherent absorbances between the wells in an ELISA plate. For 6 kinds of direct competitive ELISA kits, the LOD and ROQ predicted by the model agreed well with those obtained by experiments with real samples. It was also confirmed that the model is applicable to the prediction of uncertainty that depends on the pipetting error of the viscous antiserum solution. The model was demonstrated to be useful for estimating the LOD and ROQ of competitive ELISA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

Validated UV-Vis Spectrophotometric Method for Determination of Gabapentin using Acetyl Acetone and Formaldehyde Reagents

Gabapentin is an anticonvulsant widely used in the treatment of epilepsy.An accurate and validated spectrophotometric method was developed as an alternative method to determine gabapentin in pharmaceutical products. This is a simple, accurate, precise, selective and visible spectrophotometric method. The method is based on the measurement of drug absorbance as a result of yellow solution format...

متن کامل

UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome

The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg /mL range of hydroquinone an...

متن کامل

UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome

The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg /mL range of hydroquinone an...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 2004