Experimental Evaluation of the Clamping Pressure Distribution in a Pem Fuel Cell Using Matrix-based Piezoresistive Thin-film Sensors

نویسندگان

  • R. Montanini
  • G. Squadrito
چکیده

− The achievement of a proper and uniform pressure distribution between the membrane electrode assembly (MEA) and the bipolar plates of a proton exchange membrane fuel cell (PEMFC) is a key factor of stack design and assembly. Contact pressure levels are usually controlled by selecting an appropriate external clamping pressure on the endplates. Very few studies have been focused on the measurement of the contact pressure distribution within the fuel cell and its correlation with the applied external clamping torque. This study explores the possibility of using matrix-based piezoresistive thin-film sensors, to be placed between the MEA and the monopolar plate of a PEMFC, to investigate this correlation. Before embedding the sensor array into the fuel cell, it was validated for accuracy and repeatability by designing a pneumatic calibration device which allows to apply uniform static pressure levels over the whole sensor area. Preliminary results reported in this study showed that, as the clamping torque on the endplates is increased, the average pressure on the MEA remains almost constant but its distribution changes. The core area of the electrode becomes progressively more unloaded while average stresses on the gasket rise up, with significant stress concentration around the edge corners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation and optimization of a PEM fuel cell’s electrical and mechanical behavior

Effect of clamping pressure on electrical resistance between Gas diffusion layer (GDL) and bipolar plate is a very important parameter in Proton exchange membrane (PEM) fuel cells. For investigation of this matter some researches have been done in these years. But there is not an experimental investigation of clamping pressure effect on PEM electrical resistance. In this paper, some experimenta...

متن کامل

Finite Element Simulation and ANFIS Prediction of Dimensional Error Effect on distribution of BPP/GDL Contact Pressure in PEM Fuel Cell

Distribution of contact pressure between the bipolar plate and gas diffusion layer considerably affect the performance of proton exchange membrane fuel cell. In this regard, an adaptive neuro-fuzzy inference system (ANFIS) is developed to predict the contact pressure distribution on the gas diffusion layer due to dimensional errors of the bipolar plate ribs in a proton exchange membrane fuel ce...

متن کامل

Numerical Modeling of an Innovative Bipolar Plate Design Based on the Leaf Venation Patterns for PEM Fuel Cells

Flow channel design on bipolar plates has a direct effect on Proton Exchange Membrane (PEM) fuel cell performance. It has been found out that the flow field design has a deterministic role on the mass transport and water management, and therefore on the achieved power in PEM Fuel cells. This study concentrates on improvements in the fuel cell performance through optimization of channel dimensio...

متن کامل

Developed endplate geometry for uniform contact pressure distribution over PEMFC active area

Contact resistance among the components of a polymer exchange membrane fuel cell (PEMFC) has a crucial effect on cell performance. The geometry of the endplate plays an essential role in the contact pressure distribution over the membrane electrode assembly (MEA) and the amount of contact resistance between plates. In this work, the effects of endplate geometry on the contact pressure distribut...

متن کامل

Thickness Dependence of Sensitivity in Thin Film Tin Oxide Gas Sensors Deposited by Vapor Pyrolysis

Transparent SnO2 thin films were deposited on porcelain substrates using a chemical vapor deposition technique based on the hydrolysis of SnCl4 at elevated temperatures. A reduced pressure self-contained evaporation chamber was designed for the process where the pyrolysis of SnCl4 at the presence of water vapor was carried out. Resistive gas sensors were fabricated by providing ohmic contacts o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009