Peak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer.
نویسندگان
چکیده
Increasing numbers of patients are receiving hyperbaric oxygen therapy as an intensive care treatment, some of whom have pre-existing airway obstruction. Spirometers are the ideal instruments for measuring airway obstruction, but peak flow meters are useful and versatile devices. The behaviour of both types of device was therefore studied in a hyperbaric unit under conditions of increased pressure. It is important to have a non-electrical indicator of airway obstruction, to minimize the fire risk in the hyperoxic environment. The hypothesis was tested that, assuming that dynamic resistance is unchanged, both the Wright's standard and mini-peak flow meters would over-read peak expiratory flow (PEF) under increased pressure when compared with a volumetric spirometer, as the latter is unaffected by air density. It was postulated that a correction factor could be derived so that PEF meters could be used in this setting. Seven normal subjects performed volume-dependent spirometry to derive PEF, and manoeuvres using both standard and mini PEF meters at sea level, under hyperbaric conditions at 303, 253 and 152 kPa (3, 2.5 and 1.5 atmospheres respectively; 1 atmosphere absolute=101.08 kPa), and again at sea level. There was a progressive and significant decline in PEF with increasing pressure as measured by the spirometer (69.46+/-0.8% baseline at 303 kPa compared with 101 kPa), while the PEF meters showed a progressive increase in their readings (an increase of 7.86+/-1.69% at 303 kPa with the mini PEF meter). Using these data points, a correction factor was derived which allows appropriate values to be calculated from the Wright's meter readings under these conditions.
منابع مشابه
Peak expiratory flow at altitude.
The mini Wright peak flow meter is a useful, portable instrument for field studies but being sensitive to air density will under-read at altitude. True peak expiratory flow will increase at altitude, however, because of the decreased air density, given that dynamic resistance is unchanged. The effect of simulated altitude on peak expiratory flow (PEF) was determined in six subjects with both th...
متن کاملMeasuring peak expiratory flow in general practice: comparison of mini Wright peak flow meter and turbine spirometer.
OBJECTIVE To compare measurements of the peak expiratory flow rate taken by the mini Wright peak flow meter and the turbine spirometer. DESIGN Pragmatic study with randomised order of use of recording instruments. Phase 1 compared a peak expiratory flow type expiration recorded by the mini Wright peak flow meter with an expiration to forced vital capacity recorded by the turbine spirometer. P...
متن کاملPeak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملEvaluation of the turbine pocket spirometer.
A compact electronic spirometer, the turbine pocket spirometer, which measures the FEV1, forced vital capacity (FVC), and peak expiratory flow (PEF) in a single expiration, was compared with the Vitalograph and the Wright peak flow meter in 99 subjects (FEV1 range 0.40-5.50 litres; FVC 0.58-6.48 l; PEF 40-650 l min-1). The mean differences between the machines were small--0.05 l for FEV1, 0.05 ...
متن کاملNormal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran
Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 98 1 شماره
صفحات -
تاریخ انتشار 2000