Soft-x-ray interferometer for single-shot laser linewidth measurements.
نویسندگان
چکیده
A soft-x-ray Mach-Zehnder interferometer configuration that makes use of the time delay introduced by diffraction gratings to conduct single-shot measurements of the linewidth of soft-x-ray laser amplifiers is proposed and analyzed. The scheme was experimentally demonstrated in the near-IR region of the spectrum by measurement of the mode separation of a semiconductor laser. A symmetric configuration with compensated time delays that can be implemented for plasma diagnostics and for evaluating soft-x-ray optics is also discussed.
منابع مشابه
Single-shot soft x-ray laser linewidth measurement using a grating interferometer.
The linewidth of a 14.7 nm wavelength Ni-like Pd soft x-ray laser was measured in a single shot using a soft x-ray diffraction grating interferometer. The instrument uses the time delay introduced by the gratings across the beam to measure the temporal coherence. The spectral linewidth of the 4d1S0-4p1P1 Ni-like Pd lasing line was measured to be Δλ/λ=3×10(-5) from the Fourier transform of the f...
متن کاملTemporal coherence and spectral linewidth of an injection-seeded transient collisional soft x-ray laser.
The temporal coherence of an injection-seeded transient 18.9 nm molybdenum soft x-ray laser was measured using a wavefront division interferometer and compared to model simulations. The seeded laser is found to have a coherence time similar to that of the unseeded amplifier, ~1 ps, but a significantly larger degree of temporal coherence. The measured coherence time for the unseeded amplifier is...
متن کاملElectromagnetic-field distribution measurements in the soft x-ray range: full characterization of a soft x-ray laser beam.
We report direct measurement of the electromagnetic-field spatial distribution in a neonlike Ar capillary discharge-driven soft x-ray laser beam. The wave front was fully characterized in a single shot using a Shack-Hartmann diffractive optics sensor. The wave front was observed to be dependent on the discharge pressure and capillary length, as a result of beam refraction variations in the capi...
متن کاملLongitudinal coherence measurements of a transient collisional x-ray laser.
We present what is to our knowledge the first longitudinal coherence measurement of a transient inversion collisional x-ray laser. We investigated the picosecond output of a Ni-like Pd x-ray laser at 14.68 nm generated by the COMET laser facility at the Lawrence Livermore National Laboratory. Interference fringes were generated with a Michelson interferometer setup in which a thin multilayer me...
متن کاملSingle-optical-element soft-x-ray interferometry with a laser-plasma x-ray source.
We report on a compact interferometer for the water-window soft-x-ray range that is suitable for operation with laser-plasma sources. The interferometer consists of a single diffractive optical element that focuses impinging x rays to two focal spots. The light from these two secondary sources forms the interference pattern. The interferometer was operated with a liquid-nitrogen jet laser-plasm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 21 13 شماره
صفحات -
تاریخ انتشار 1996