Rapid high-performance liquid chromatographic determination of docetaxel (Taxotere) in plasma using liquid-liquid extraction.

نویسندگان

  • J Ciccolini
  • J Catalin
  • M F Blachon
  • A Durand
چکیده

A new rapid and sensitive high-performance liquid chromatographic method for analysis of docetaxel (Taxotere) in human plasma was developed and validated. After adding an internal standard (paclitaxel, Taxol), plasma was extracted following a simple liquid-liquid extraction with diethyl ether. Extraction efficiency averaged 95% for docetaxel. Separation was performed using a Nucleosil (C18) 5 microm column, monitored at 227 nm. The isocratic mobile phase consisted of acetonitrile-acetate buffer, pH 5-tetrahydrofuran (45:50:5, v/v) pumped at a flow-rate of 1.8 ml/min. The limit of quantification for docetaxel in plasma was 12.5 ng/ml. Retention times for docetaxel and paclitaxel were 7.7 and 9 min, respectively. Standard curves were linear over a range of 25-1,000 ng/ml. This new method is rapid since it does not require time-consuming extraction procedures, or complex chromatographic conditions. This rapidity, along with the lack of chromatographic interferences with various other drugs likely to be administered to the cancer patients (pain killers, corticoids, antiemetics drugs) make this method suitable for daily routine analysis of Taxotere, a major anticancer drug extensively used in clinical oncology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. B, Biomedical sciences and applications

دوره 759 2  شماره 

صفحات  -

تاریخ انتشار 2001