Surface plasmon resonance sensor for domoic acid based on grafted imprinted polymer.
نویسندگان
چکیده
A molecularly imprinted polymer (MIP) film for domoic acid (DA) was synthesised by direct photo-grafting onto a gold chip suitable for a surface plasmon resonance (SPR) based bioanalytical instrument system, the BIAcore 3000. The gold surface was first functionalised with a self-assembled monolayer of 2-mercaptoethylamine and subsequent carbodiimide chemistry was performed for covalent attachment of the photoinitiator, 4,4'-azobis(cyanovaleric acid). This ensured that the formation of the MIP thin film, comprising 2-(diethylamino) ethyl methacrylate as functional monomer and ethylene glycol dimethacrylate as cross-linker, occurred only at the surface level. Optimisation and control over the grafting procedure were achieved using contact angle measurements and atomic force microscope (AFM) imaging. The surface grafting resulted in the formation of thin and homogeneous MIP film with thickness of 40 nm. A competitive binding assay was performed with free DA and its conjugate with horseradish peroxidase, which was used as a refractive label. The sensor was evaluated for its sensitivity, cross-reactivity, and robustness by using a BIAcore 3000. Likewise, monoclonal antibodies acting as natural receptors for the toxin were studied with the same BIAcore system. Results of a comparison between the artificial and natural receptors are reported. In contrast to monoclonal antibodies, the regeneration of MIP chip did not affect its recognition properties and continuous measurement was possible over a period of at least 2 months.
منابع مشابه
Use of laser-triggered gold nanoparticle-grafted dual light and temperature-responsive polymeric sensor for the recognition of thioguanine as anti-tumor agent
Objective(s): Today, there is an urgent need for improved sensor materials for drug sensing and effective monitoring and interventions in this area are highly required to struggle drug abuse. The present study aimed to synthesize a thioguanine-responsive sensor based on a nanocomposite consisting of AuNP-grafted light- and temperature-responsive poly butylmethacrylate-co-acrylamide-co-methacryl...
متن کاملUltrathin molecularly imprinted polymer sensors employing enhanced transmission surface plasmon resonance spectroscopy.
An ultrathin novel nanosensor (31.5 +/- 4.1 nm thick in the absence of analytes), employing a molecularly imprinted polymer as a recognition element for cholesterol and gold nanoparticle enhanced transmission surface plasmon resonance spectroscopy for detection, was constructed.
متن کاملFabrication and Characterization of the Fiber Optical Taper for a Surface Plasmon Resonance Sensor
For a fiber optical surface plasmon resonance (SPR) sensor a short part of its cladding should be removed to coat a thin layer of a metal. Usually this is problematic when an optical fiber with small core diameter is used. In this paper, a new method using µliter droplet of the HF acid for short fiber optical taper fabrication is reported. Using this method in a multi-mode optical fiber w...
متن کاملBehenic Acid Monolayer and Bilayer Assemblies- A Study of Concanavalin A (Con A) Adsorption and its Interaction with Dextran Using Surface Plasmon Resonance Spectroscopy and Microscopy
Deposition of behenic acid (B.A) mono and bilayers onto gold coated surfaces was performed by Langmuir-Blodget dip-casting technique. Surface Plasmon resonance (SPR) and ellipsometry methods were employed for investigation of the monolayer and bilayer films. The adsorption of the biologically important molecule Concanavalin A (Con A) from bulk solution to these monolayers and bilayers as we...
متن کاملA novel polymerization of ultrathin sensitive imprinted film on surface plasmon resonance sensor.
A new surface-initiated polymerization based on pasting the initiator on a sensor chip surface was applied to prepare a malachite green (MG) imprinted ultrathin film on a surface plasmon resonance (SPR) sensor. First, the initiator (2,2-azoisobutyronitrile) was pasted on the gold surface using polyvinyl chloride (PVC). The initiator-covered gold chip was then soaked in a pre-polymerization solu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 20 2 شماره
صفحات -
تاریخ انتشار 2004