Coins can be safely removed from the esophagus by Foley's catheter without fluoroscopic control.

نویسندگان

  • S Agarwala
  • V Bhatnagar
  • D K Mitra
چکیده

OBJECTIVE Evaluate safety of the procedure of removing coins from the esophagus in children by Foley's catheter without fluoroscopic control. DESIGN Retrospective case-series. SETTING Tertiary care referral hospital, during 1992-94. SUBJECTS 302 consecutive children with coins impacted in the esophagus who presented to the hospital. RESULTS Coins were successfully removed in 283 (93.7%) children including 2 cases in whom the removal was difficult. CONCLUSIONS Foley's catheter may be used for removed of impacted esophageal coins, even without fluoroscopic control. The technique is effective and safe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of coins from oesophagus with Foley catheter under ketamine effect.

BACKGROUND Foreign body ingestion continues to be a common problem that contributes significantly to high morbidity and mortality worldwide. Coins are the most common foreign body lodged in the oesophagus. This study was conducted to describe our experience of removal of coins from oesophagus with Foley catheter under ketamine effect. METHODS This was a retrospective study conducted at Distri...

متن کامل

Removal of coin from upper esophageal tract in children with Magill's forceps under propofol sedation.

Foreign body ingestion is a common emergency problem in children. Coins are the most common foreign bodies lodged in the esophagus. This is a retrospective study where we reviewed 21 consecutive paediatric cases of coins impacted in the upper esophagus. These children were attended at the BP Koirala Institute of Health Sciences, Dharan, from March 2007 to March 2008. In this study, Mc-Intosh la...

متن کامل

Pharyngeal coin removal in children.

Two cases of coin extraction from the upper third of the oesophagus are described, using a Foley catheter in the accident and emergency department without complication. Although previously reported, the method is not widely used; indeed many junior doctors appear unaware of it. Coins can be removed from this proximal position provided the operator is confident and swift. This appears to be a sa...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology

A technological platform (MediGuide) has been recently introduced for non-fluoroscopic catheter tracking. In several studies, we have demonstrated that the application of this non-fluoroscopic catheter visualization system (NFCV) reduces fluoroscopy time and dose by 90-95% in a variety of electrophysiology (EP) procedures. This can be of relevance not only to the patients, but also to the nurse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian pediatrics

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 1996