The use of percutaneous suture-mediated closure for the management of 14 French femoral venous access.
نویسندگان
چکیده
BACKGROUND Little has been reported regarding the utility or outcomes of femoral venous vascular closure using arterial suture closure devices. We describe results using a pre-closure approach with a 6 French (Fr) Perclose Closer S device in patients who underwent antegrade aortic valvuloplasty using 14 Fr percutaneous femoral venous access catheters. METHODS Forty-five patients underwent antegrade aortic valvuloplasty and suture-mediated closure with a 6 Fr Perclose device. A 6 Fr Closer S suture device was preloaded into the femoral vein after 6 Fr sheath access, prior to insertion of a 14 Fr venous sheath. Upon completion of the procedure, the 14 Fr femoral venous sheath was removed through the existing sutures. RESULTS Of 45 patients (mean age 82.4 years; 17 males), immediate hemostasis was achieved with percutaneous suture closure in 43 (95.6%). Only 2 failures occurred which were subsequently successfully treated with manual compression. No late access site bleeding occurred from sutured sites. In all other patients, hemostasis using a 6 Fr Perclose suture-mediated device was successful and immediate. There was no need for transfusion, no clinical venous thrombosis, and no infections occurred at the access site. Two hospital deaths were documented from causes unrelated to suture-mediated closure. CONCLUSIONS In conjunction with 14-Fr size percutaneous sheaths during antegrade aortic valvuloplasty, percutaneous suturemediated closure is a highly effective method for achieving hemostasis. This has simplified postprocedural management in terms of early mobilization and diminished late access site bleeding.
منابع مشابه
Total percutaneous endovascular aneurysm repair with the dual 6-F Perclose-AT preclosing technique: a case-control study.
PURPOSE To determine the safety and efficacy of total percutaneous access closure for endovascular aortic aneurysm repair with a suture-mediated preclosing technique. MATERIALS AND METHODS One hundred thirty-two femoral access sites in 70 patients who underwent endovascular aortic aneurysm repair were closed percutaneously with off-label use of two F-6 Perclose AT devices preapplied at a 90 d...
متن کامل[Immediate and long-term results of percutaneous suture of femoral access-site after endovascular treatment of thoracic aortic disease].
The use of stent grafts for treating diseases of the aorta has been assisted by the development of new percutaneous techniques for closing the access site. The purpose of this study is to describe our clinical experience and results obtained using percutaneous closure devices for femoral artery closure after the placement of stent grafts.
متن کاملComplications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study.
PURPOSE To evaluate the incidence and types of complications encountered with use of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure in a retrospective case-controlled study. MATERIALS AND METHODS The authors identified 100 consecutive patients, 15 men and 85 women 21-85 years of age (mean, 50 years), between December 2000 and July 2001 in whom ...
متن کاملPercutaneous Zenith endografting for abdominal aortic aneurysms.
A completely percutaneous approach to infrarenal abdominal aortic aneurysm (AAA) endografting has the theoretic benefits of being minimally invasive and more expedient. Our goal was to demonstrate the utility of this approach using a suprarenal fixation device and a suture-mediated closure system. We conducted a single-institution, retrospective review of 14 patients who underwent percutaneous ...
متن کاملPercutaneous repair of aortic aneurysms: a prospective study of suture-mediated closure devices.
PURPOSE To evaluate prospectively the safety and efficacy of totally percutaneous placement of abdominal and thoracic aortic endografts using the Prostar XL suture-mediated closure system. METHODS From January 2002 to January 2005, we attempted to insert percutaneously all bifurcated abdominal aortic and thoracic endografts. Consecutive patients (25 men, four women), with mean age 74.9 years ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of invasive cardiology
دوره 18 7 شماره
صفحات -
تاریخ انتشار 2006