Limited Tomography Reconstruction via Tight Frame and Simultaneous Sinogram Extrapolation
نویسندگان
چکیده
X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the projection data. In the case of limited data, the inverse problem of CT becomes more ill-posed, which makes the reconstructed image deteriorated by the artifacts. In this paper, we consider two dimensional CT reconstruction using the projections truncated along the spatial variable in the Radon domain. Over the decades, the numerous results including the sparsity model based approach has enabled the reconstruction of the image inside the region of interest (ROI) from the limited knowledge of the data. However, unlike these existing methods, we try to reconstruct the entire CT image from the limited knowledge of the sinogram via the tight frame regularization and the simultaneous sinogram extrapolation. Our proposed model shows more promising numerical simulation results compared with the existing sparsity model based approach. Mathematics subject classification: 65N20, 65N21, 94A08
منابع مشابه
TGV sinogram inpainting for limited angle tomography
X-ray computed tomography (CT) plays a very important role in daily biomedical practice for diagnosis and therapy, and in materials science for accurate data analysis and quality control. Besides accurate and robust image reconstruction, there is a growing interest in methods for limited angle tomography. The idea is to reduce the X-ray dose delivered to patients or to cope with physical angle ...
متن کاملGrid processing techniques for the iterative reconstruction of large clinical positron emission tomography sinogram datasets
We have developed, implemented and validated a set of flexible and efficient iterative image reconstruction (IIR) and processing methods for clinical positron emission tomography (PET) static or dynamic studies. IIR techniques are shown to produce images of better contrast and signal-to-noise ratio than the conventional filtered back-projection (FBP). Their high computational cost has been a si...
متن کاملSinogram Interpolation Method for Sparse-Angle Tomography
In sparse-angle X-ray tomography reconstruction, where only a small number of projection images are taken around the object, appropriate sinogram interpolation has a significant impact on image quality. A novel sinogram interpolation method is introduced for extreme sparse tomographic reconstruction where only nine measured projection images are available. The sinogram is interpolated by solvin...
متن کاملLose The Views: Limited Angle CT Reconstruction via Implicit Sinogram Completion
Computed Tomography (CT) reconstruction is a fundamental component to a wide variety of applications ranging from security, to healthcare. The classical techniques require measuring projections, called sinograms, from a full 180° view of the object. This is impractical in a limited angle scenario, when the viewing angle is less than 180°, which can occur due to different factors including restr...
متن کاملImproved emission tomography via multiscale sinogram analysis
In this paper, we extend a multiscale Bayesian approach to modeling and estimation of general Poisson processes previously developed in [1] by the first two authors, and apply it to the emission computed tomography (ECT) image reconstruction problem. We develop a practical prior model for the sinogram image, which we use to estimate the underlying sinogram intensity from the raw projection data...
متن کامل