The use of hydrazine-based derivatization reagents for improved sensitivity and detection of carbonyl containing compounds using MALDI-MSI.
نویسندگان
چکیده
Hydrazine-based derivatization reagents have been used to detect the presence of the carbonyl containing glucocorticoid fluticasone proprionate in rat lung tissue by MALDI-MSI. Such reagents also act as a matrix for analysis by MALDI-MS and have been termed "reactive matrices". Cryosections of rat lung tissue (12 μm), spotted with a range of concentrations of fluticasone proprionate, were derivatized in situ with 2,4-dinitrophenylhydrazine (DNPH) and 4-dimethylamino-6-(4-methoxy-1-naphthyl)-1,3,5-triazine-2-hydrazine (DMNTH) by the use of an acoustic reagent spotter. It has been demonstrated that DMNTH gave superior results compared to DNPH and that analysis of samples immediately after application of DMNTH resulted in the detection of the protonated hydrazone derivative ([MD + H](+)) of fluticasone propionate at a concentration of 500 ng/μL. It has been further shown that a prolonged reaction time (~48 h) improves the detection limit of the protonated hydrazone derivative to 50 ng/μL and that improvements in sensitivity and limits of detection are obtained when a conventional MALDI matrix CHCA is employed in conjunction with the DNPH/DMNTH reactive matrix.
منابع مشابه
Comparative Gas Chromatography of Halides Using Different Substituted Phenylboronic Acids as Derivatizing Reagents
The GC of halides (chloride, bromide and iodide) using phenylboronic acid (PBA), 4-bromophenylboronic acid (BPBA), 3, 5 bis (trifluoromethyl) phenylboronic acid (FPBA) and 2,4- dichlorophenylboronic acid (CPBA) as derivatizing reagents are compared. The reactions are carried out in the presence of mercuric salts. The detection systems used are FID and ECD. The thermal analysis of the compou...
متن کاملElectron-capturing derivatization of neutral steroids for increasing sensitivity in liquid chromatography/negative atmospheric pressure chemical ionization-mass spectrometry.
Derivatization of neutral steroids for increasing sensitivity in liquid chromatography/negative atmospheric pressure chemical ionization-mass spectrometry (APCI-MS) has been examined. Under APCI conditions, gas-phase electrons are provided by the corona discharge and captured by electron-affinitive compounds. In negative APCI-MS, therefore, ultrahigh sensitivity can be obtained by tagging neutr...
متن کاملOn-Tissue Derivatization via Electrospray Deposition for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging of Endogenous Fatty Acids in Rat Brain Tissues
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is used for the multiplex detection and characterization of diverse analytes over a wide mass range directly from tissues. However, analyte coverage with MALDI MSI is typically limited to the more abundant compounds, which have m/z values that are distinct from MALDI matrix-related ions. On-tissue analyte deriva...
متن کاملMALDI mass spectrometry imaging in oncology (Review).
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) has improved over the years and is increasingly being used for biomarker discovery directly from human tissue sections. State-of-the-art technology currently enables a resolution down to 20 µm. MSI therefore allows the correlation of spatial and temporal protein expression profiles with distinct morphological fe...
متن کاملDetection of Microsatellite Instability by High-Resolution Melting Analysis in Colorectal Cancer
Background: Colorectal cancer (CRC) is the third most common cancer worldwide. microsatellite instability (MSI) is a molecular marker of a deficient mismatch repair system and happens in almost 15% of CRCs. Because of a wide frequency of MSI+ CRC in Iran compared to other parts of the world, the importance of screening for this type of cancer is highlighted. Methods: The most common MSI detecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 407 8 شماره
صفحات -
تاریخ انتشار 2015