This study present electromyographic (EMG) signal to torque model and investigates the effects of various factors on EMG signal and EMG to torque model. Pre-processing techniques are applied on EMG signal in order to remove the DC offset, 60 Hz noise and to estimate the EMG amplitude. The estimated EMG amplitude is then mapped to joint torque using a new non-linear equation. This equation uses some parameters, whose values are obtained using nonlinear regression. Ten subjects took part in the experiments and performed variable force maximal voluntary contractions (MVC) and submaximal voluntary contractions (SMVC). The resulting elbow joint torque and EMG signals were preprocessed and entered to the model to find value of the parameters using nonlinear regression. Once these values were obtained they were put into the model and thus joint torque was estimated. Also EMG is analysed for effect of various factors like muscle fatigue, cross talk and different joint velocity. The results obtained from this model are highly correlated with the true values of the torque and the average correlation and mean square error for different experiments are 0.9997 and 0.047 Nm respectively. This new mathematical equation can be used to design a control system for rehabilitation and wearable robots.
منابع مشابه
Evaluation of Elbow Stretch Reflex Using a Portable Hand-driven Isokinetic System in Normal Adults
OBJECTIVE To evaluate normal healthy persons without spasticity to observe normal findings of the elbow stretch reflex using a newly developed, portable, hand-driven spasticity-measuring system. METHOD Thirty normal persons without any disease involving the central or peripheral nervous system were enrolled in this study. The portable hand-driven isokinetic system is able to measure the joint...
متن کاملInfluence of joint angle on EMG-torque model during constant-posture, quasi-constant-torque contractions.
Electromyogram (EMG)-torque modeling is of value to many different application areas, including ergonomics, clinical biomechanics and prosthesis control. One important aspect of EMG-torque modeling is the ability to account for the joint angle influence. This manuscript describes an experimental study which relates the biceps/triceps surface EMG of 12 subjects to elbow torque at seven joint ang...
متن کاملEffect of sex on torque, recovery, EMG, and MMG responses to fatigue
OBJECTIVE The purpose of the present investigation was to examine the effect of sex on maximal voluntary isometric contraction (MVIC) torque and the EMG and MMG responses as a result of fatiguing, intermittent, submaximal (65% of MVIC), isometric elbow flexion muscle contractions. METHODS Eighteen men and women performed MVIC trials before (pretest), after (posttest), and 5-min after (5-min r...
متن کاملEstimation and application of EMG amplitude during dynamic contractions.
The sections above have described an EMG amplitude estimator and an initial application of this estimator to the EMG-torque problem. The amplitude estimator consists of six stages. In the first stage, motion artifact and power-line interference are attenuated. Motion artifact is typically removed with a highpass filter. Elimination of power-line noise is more difficult. Commercial systems tend ...
متن کاملComparative Analysis of Wavelet-based Feature Extraction for Intramuscular EMG Signal Decomposition
Background: Electromyographic (EMG) signal decomposition is the process by which an EMG signal is decomposed into its constituent motor unit potential trains (MUPTs). A major step in EMG decomposition is feature extraction in which each detected motor unit potential (MUP) is represented by a feature vector. As with any other pattern recognition system, feature extraction has a significant impac...
متن کامل