Determination of trace anions in high-nitrate matrices by ion chromatography.
نویسندگان
چکیده
An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using the EG40, performance at trace levels was enhanced because background conductivity decreased and retention time reproducibility improved. Trace anionic contamination from the mobile phase was minimized when using the eluent generator compared to using conventionally prepared sodium hydroxide eluents. The signal-to-noise ratio was also improved with the use of a temperature controlled conductivity cell and chromatography hardware in the microbore (2-mm) format. The eluent concentration was optimized to separate the contaminant anions from the excess of the nitrate matrix ions. The procedure was demonstrated for a solution of reagent-grade sodium nitrate and high-purity 0.7% nitric acid. Method detection limits for chloride, sulfate and phosphate of 150 microg/l and lower were achieved.
منابع مشابه
Partition/Ion-Exclusion Chromatographic Ion Stacking for the Analysis of Trace Anions in Water and Salt Samples by Ion Chromatography.
A new analytical methodology for a simple and efficient on-line preconcentration of trace inorganic anions in water and salt samples prior to ion chromatographic determination is proposed. The preconcentration method is based on partition/ion-exclusion chromatographic ion stacking (PIEC ion stacking) with a hydrophilic polymer gel column containing a small amount of fixed anionic charges. The d...
متن کاملDetermination of trace levels of haloacetic acids and perchlorate in drinking water by ion chromatography with direct injection.
Disinfection by products of haloacetic acids and perchlorate pose significant health risks, even at low microg/l levels in drinking water. A new method for the simultaneous determination of nine haloacetic acids (HAAs) and perchlorate as well as some common anions in one run with ion chromatography was developed. The HAAs tested included mono-, di-, trichloroacetic acids, mono, di-, tribromoace...
متن کاملAnalysis of anion constituents of urine by inorganic capillary electrophoresis.
Inorganic capillary electrophoresis (ICE) is a new separations technology which melds the technique of classical electrophoresis with the separations approach of ion chromatography. Matrices which have been difficult to deal with using ion chromatography have proven amenable to analysis by ICE. The simultaneous analysis of weak acid anions, oxalate and citrate and inorganic anions, chloride, su...
متن کاملSimplified column-switching technology for the determination of traces of anions in the presence of high concentrations of other anions.
A binary eluent model was proposed to study the retention behavior of trace anions in the presence of high concentrations of co-eluent anions. According to this model, the effect of the matrix on the retention of trace anions can be suppressed by using a high-concentration eluent. Based on the model, a simplified 'heart-cut' column-switching technology was proposed, in which the column-switchin...
متن کاملChemiluminescence nitrogen detection in ion chromatography for the determination of nitrogen-containing anions.
Chemiluminescence nitrogen detection (CLND) provides equimolar response for nitrogen-containing ions such as nitrate, nitrite, cyanide, ammonium and tetradecyltrimethylammonium. Only azide yields a lower response. Nitrite, azide and nitrate are separated on a Dionex AS11 column using 5 nM NaOH as eluent with a 3 microM (1 ng N) limit of detection. Matrices, such as 1:10 diluted seawater, do not...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 920 1-2 شماره
صفحات -
تاریخ انتشار 2001