Comparison of signal quality between EASI and Mason-Likar 12-lead electrocardiograms during physical activity.

نویسندگان

  • Annika Welinder
  • Leif Sörnmo
  • Dirk Q Feild
  • Charles L Feldman
  • Jonas Pettersson
  • Galen S Wagner
  • Olle Pahlm
چکیده

BACKGROUND Myoelectric noise and baseline wander, artifacts that appear when patients move during electrocardiographic monitoring, can cause false alarms. This problem can be addressed by using a reduced lead set and placing electrodes on the anterior part of the torso only. The Mason-Likar modification of the standard 12-lead electrocardiogram and the EASI lead system are 2 alternative systems for lead placement. OBJECTIVES To test the hypothesis that the EASI lead system is less susceptible to artifacts than is the Mason-Likar modification of the standard 12-lead electrocardiogram. METHODS Baseline wander and myoelectric noise amplitudes of EASI and Mason-Likar 12-lead electrocardiograms were compared. Twenty healthy volunteers participated. Both lead systems were recorded simultaneously for different types of physical activities. For each lead in each subject, baseline wander and myoelectric noise were measured for both systems, at rest and during each physical activity. RESULTS The outcome for baseline wander was mixed. For myoelectric noise content, the EASI system performed better for the limb leads in the different physical activities. In the precordial leads, the differences were minimal or mixed. However, for supine-to-right turning, EASI performed worse than the Mason-Likar system. CONCLUSIONS The 2 systems have similar susceptibilities to baseline wander. The EASI system is, however, less susceptible to myoelectric noise than is the Mason-Likar system. EASI performed worse than Mason-Likar for turning supine to right, because only the EASI system uses an electrode in the right-midaxillary line.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ECG monitoring leads and special leads

ECG monitoring is common place in the hospital and even pre-hospital setting. The need for different types of lead systems in different settings has been emphasised. Simple three electrode bipolar recording is ubiquitous for monitoring. This can be used to record modified bipolar chest leads as well. Using five leads gives the option of getting a chest lead in addition to bipolar limb leads, en...

متن کامل

Comparison of the spatial QRS-T angle derived from digital ECGs recorded using conventional electrode placement with that derived from Mason-Likar electrode position.

BACKGROUND The spatial QRS-T angle is ideally derived from orthogonal leads. We compared the spatial QRS-T angle derived from orthogonal leads reconstructed from digital 12-lead ECGs and from digital Holter ECGs recorded with the Mason-Likar (M-L) electrode positions. METHODS AND RESULTS Orthogonal leads were constructed by the inverse Dower method and used to calculate spatial QRS-T angle by...

متن کامل

Immediate Lead Positioning Feedback for ML based wearable ECG

Wearable ECG devices are used in combination with smartphones to capture, analyze and transmit ECG data to far away hospitals where doctors analyze, diagnose and provide necessary patient feedback. ECG electrode cable misplacement is a significant challenge when untrained patients use them, especially among rural population. Lead misplacement algorithms exists for standard ECG electrode positio...

متن کامل

مقایسه کیفیت زندگی زنان سالمند فعال و غیرفعال با تأکید بر فعالیت‌های بدنی

Objectives Among different people, especially the elderly who are undergoing their specific physical, emotional, and psychological conditions, quality of life is considered an issue that is of paramount importance. The present study aims to make a comparison between the quality of life in elderly women who lead an active life with those with a non-active one with special emphasis on physical ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of critical care : an official publication, American Association of Critical-Care Nurses

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2004