Scan-rescan reproducibility of quantitative assessment of inflammatory carotid atherosclerotic plaque using dynamic contrast-enhanced 3T CMR in a multi-center study

نویسندگان

  • Huijun Chen
  • Jie Sun
  • William S Kerwin
  • Niranjan Balu
  • Moni B Neradilek
  • Daniel S Hippe
  • Daniel Isquith
  • Yunjing Xue
  • Kiyofumi Yamada
  • Suzanne Peck
  • Chun Yuan
  • Kevin D O’Brien
  • Xue-Qiao Zhao
چکیده

BACKGROUND The aim of this study is to investigate the inter-scan reproducibility of kinetic parameters in atherosclerotic plaque using dynamic contrast-enhanced (DCE) cardiovascular magnetic resonance (CMR) in a multi-center setting at 3T. METHODS Carotid arteries of 51 subjects from 15 sites were scanned twice within two weeks on 3T scanners using a previously described DCE-CMR protocol. Imaging data with protocol compliance and sufficient image quality were analyzed to generate kinetic parameters of vessel wall, expressed as transfer constant (K trans ) and plasma volume (v p ). The inter-scan reproducibility was evaluated using intra-class correlation coefficient (ICC) and coefficient of variation (CV). Power analysis was carried out to provide sample size estimations for future prospective study. RESULTS Ten (19.6%) subjects were found to suffer from protocol violation, and another 6 (11.8%) had poor image quality (n=6) in at least one scan. In the 35 (68.6%) subjects with complete data, the ICCs of K trans and v p were 0.65 and 0.28, respectively. The CVs were 25% and 62%, respectively. The ICC and CV for v p improved to 0.73 and 28% in larger lesions with analyzed area larger than 25 mm2. Power analysis based on the measured CV showed that 50 subjects per arm are sufficient to detect a 20% difference in change of K trans over time between treatment arms with 80% power without consideration of the dropout rate. CONCLUSION The result of this study indicates that quantitative measurement from DCE-CMR is feasible to detect changes with a relatively modest sample size in a prospective multi-center study despite the limitations. The relative high dropout rate suggested the critical needs for intensive operator training, optimized imaging protocol, and strict quality control in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inflammatory Atherosclerotic Plaque Can Be Reproducibly Assessed By 3T Dynamic Contrast Enhanced MRI for Multi- Center Studies

Introduction Inflammation plays an important role in both atherosclerotic plaque progression and rupture [1], which has led to an interest in treatments with anti-inflammatory effects. To assess and monitor inflammation in vivo, dynamic contrast-enhanced (DCE) MRI has been previously demonstrated [2]. Kinetic parameters derived from DCE-MRI, including the transfer constant (K) and partial plasm...

متن کامل

Increasing the Spatial Resolution of 3T Carotid MRI Has No Beneficial Effect for Plaque Component Measurement Reproducibility

PURPOSE Different in-plane resolutions have been used for carotid 3T MRI. We compared the reproducibility, as well as the within- and between reader variability of high and routinely used spatial resolution in scans of patients with atherosclerotic carotid artery disease. Since no consensus exists about the optimal segmentation method, we analysed all imaging data using two different segmentati...

متن کامل

In-vivo carotid T2 mapping can accurately quantify plaque lipid content to discriminate between symptomatic and asymptomatic patients: histological validation, scan-rescan reproducibility and clinical study

Background In-vivo carotid CMR is able to identify features of plaque vulnerability such as lipid core size. However, the current standard (multicontrast CMR) requires contrast media, extensive post-processing and subjective interpretation. Recently we proposed to use quantitative T2 mapping to distinguish plaque lipid from surrounding fibrous tissue and measure lipid core size. This study aime...

متن کامل

Reproducibility of Dynamic Contrast-Enhanced MRI in Renal Cell Carcinoma

The objective of this study was to investigate the intra- and interobserver as well as scan-rescan reproducibility of quantitative parameters of renal cell carcinomas (RCCs) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). A total of 21 patients with clear cell RCCs (17 men, 4 woman; age 37-69 years, mean age 54.6 years, mean size, 5.0 ± 2.2 cm) were prospectively recruited ...

متن کامل

Reader and platform reproducibility for quantitative assessment of carotid atherosclerotic plaque using 1.5T Siemens, Philips, and General Electric scanners.

PURPOSE To evaluate the platform and reader reproducibility of quantitative carotid plaque measurements. MATERIALS AND METHODS A total of 32 individuals with >or=15% carotid stenosis by duplex ultrasound were each imaged once by a 1.5T General Electric (GE) whole body scanner and twice by either a 1.5T Philips scanner or a 1.5T Siemens scanner. A standardized multisequence protocol and identi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014