Efficacy and workload analysis of a fixed vertical couch position technique and a fixed‐action–level protocol in whole‐breast radiotherapy
نویسندگان
چکیده
Quantification of the setup errors is vital to define appropriate setup margins preventing geographical misses. The no-action-level (NAL) correction protocol reduces the systematic setup errors and, hence, the setup margins. The manual entry of the setup corrections in the record-and-verify software, however, increases the susceptibility of the NAL protocol to human errors. Moreover, the impact of the skin mobility on the anteroposterior patient setup reproducibility in whole-breast radiotherapy (WBRT) is unknown. In this study, we therefore investigated the potential of fixed vertical couch position-based patient setup in WBRT. The possibility to introduce a threshold for correction of the systematic setup errors was also explored. We measured the anteroposterior, mediolateral, and superior-inferior setup errors during fractions 1-12 and weekly thereafter with tangential angled single modality paired imaging. These setup data were used to simulate the residual setup errors of the NAL protocol, the fixed vertical couch position protocol, and the fixed-action-level protocol with different correction thresholds. Population statistics of the setup errors of 20 breast cancer patients and 20 breast cancer patients with additional regional lymph node (LN) irradiation were calculated to determine the setup margins of each off-line correction protocol. Our data showed the potential of the fixed vertical couch position protocol to restrict the systematic and random anteroposterior residual setup errors to 1.8 mm and 2.2 mm, respectively. Compared to the NAL protocol, a correction threshold of 2.5mm reduced the frequency of mediolateral and superior-inferior setup corrections with 40% and 63%, respectively. The implementation of the correction threshold did not deteriorate the accuracy of the off-line setup correction compared to the NAL protocol. The combination of the fixed vertical couch position protocol, for correction of the anteroposterior setup error, and the fixed-action-level protocol with 2.5 mm correction threshold, for correction of the mediolateral and the superior-inferior setup errors, was proved to provide adequate and comparable patient setup accuracy in WBRT and WBRT with additional LN irradiation.
منابع مشابه
Comparison of different TBI techniques in terms of dose homogeneity
Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملEvaluation of regional nodes irradiation during breast cancer radiotherapy
Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...
متن کاملeNAL++: a new and effective off‐line correction protocol for rotational setup errors when using a robotic couch
Cone-beam CTs (CBCTs) installed on a linear accelerator can be used to provide fast and accurate automatic six degrees of freedom (6DoF) vector displacement information of the patient position just prior to radiotherapy. These displacement corrections can be made with 6DoF couches, which are primarily used for patient setup correction during stereotactic treatments. When position corrections ar...
متن کاملDosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...
متن کامل