Phase Demodulation in Angular Vibration Measurements

نویسنده

  • Jiří TŮMA
چکیده

The paper deals with the problem of angular vibration measurements in time history of rotation angle, angular velocity or angular acceleration. The source of information about angular vibrations is an encoder producing an impulse signal. It is supposed that the impulse frequency is changed proportionally to the rotational frequency. A time record of an impulse signal is transformed to an analytical signal using Hilbert transformation. The unwrapped phase of the analytical signal gives the rotation angle, which is employed to evaluation of angular velocity and angular acceleration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rolling Bearing Fault Analysis by Interpolating Windowed DFT Algorithm

This paper focuses on the problem of accurate Fault Characteristic Frequency (FCF) estimation of rolling bearing. Teager-Kaiser Energy Operator (TKEO) demodulation has been applied widely to rolling bearing fault detection. FCF can be extracted from vibration signals, which is pre-treatment by TEKO demodulation method. However, because of strong noise background of fault vibration signal, it is...

متن کامل

Employing dual frequency phase sensitive demodulation technique to improve the accuracy of voltage measurement in magnetic induction tomography and designing a labratoary prototype

Magnetic induction tomography (MIT) is a promising modality for noninvasive imaging due to its contactless technology. Being a non-contact safe imaging technique, MIT has been an appropriate method in compare to other electrical tomography. In this imaging method, a primary magnetic field is applied by excitation coils to induce eddy currents in the material to be studied and a secondary magnet...

متن کامل

Heterodyne Angle Deviation Interferometry in Vibration and Bubble Measurements

We proposed heterodyne angle deviation interferometry (HADI) for angle deviation measurements. The phase shift of an angular sensor (which can be a metal film or a surface plasmon resonance (SPR) prism) is proportional to the deviation angle of the test beam. The method has been demonstrated in bubble and speaker’s vibration measurements in this paper. In the speaker’s vibration measurement, th...

متن کامل

Phase-resolved heterodyne holographic vibrometry with a strobe local oscillator.

We report a demonstration of phase-resolved vibrometry, in which out-of-plane sinusoidal motion is assessed by heterodyne holography. In heterodyne holography, the beam in the reference channel is an optical local oscillator (LO). It is frequency-shifted with respect to the illumination beam to enable frequency conversion within the sensor bandwidth. The proposed scheme introduces a strobe LO, ...

متن کامل

Paper A Structured Light 3-D Acquisition System with a CMOS Image Sensor for Background Suppression and Frequency and Phase Detection

We propose and demonstrate a 3-D acquisition system with background suppression capability based on a structured light projection method. We have designed and demonstrated CMOS image sensor for frequency and phase detection by in-pixel digital demodulation circuit. The demodulation circuits suppress background light and extract modulated signal light that encodes angular information in frequenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002